LED Diagnostics & Troubleshooting

Flashes

red x 11

Flashes

red x 2

Flashes

red x 9

Flashes

red x 1

Solid

green

x3 sec

Flashes

green

Solid

Off

Flashes

green

Flashes red 

& orange

Flashes

green

Flashes

orange

x5

Flashes

orange

x4

Flashes

orange

x3

Flashes

orange

x2

Flashes

orange

x1

LED

Status

Description

Troubleshooting

Module Programming

Off

Module has no power.

Check the power connections.

Solid red

Module is powered. Waiting for 
programming to begin.

Check if the ignition input is properly connected.

Flashing green
continuously

Module has detected IGN ON. 
Detection in progess.

The CAN wires may be incorrectly connected. Refer to 
the wiring diagram to make the right connections. 

Solid green for 3 
seconds

Module was successfully 
programmed with transponder.

Normal operation.

Module Programming - Error codes

Flashes red x 1

FT CAN not detected

The CAN wires may be incorrectly connected. Refer to 
the wiring diagram to make the right connections. 

Flashes red x 2

HS CAN not detected

The CAN wires may be incorrectly connected. Refer to 
the wiring diagram to make the right connections. 

Flashes red x 9

Invalid CAN network

The CAN was detected but the ignition message on CAN 
is not detected. Check if the firmare is correct.

Flashes red x 11

Internal error

Report issue to technical support 

External Module Synchronisation

Flashes red, red, 
then orange x 10

OBDII feature not supported.

Diagnostic data bus not detected. Some features are not 
supported by SmartStart. This can be caused by missing 
wire connections or module hardware limitation. Refer to 
the wiring installation section to check the connections.

Active Ground While Running

Flashes green

GROUND OUT ON (GWR) 
command received.

Otherwise, the Ground While Running (status) signal was 
lost or was never received by the module. Commands 
can come from RF, D2D or W2W.

Flashes red & 
orange

IGNITION ON command 
received.

Otherwise, the ignition signal was not received by the 
module. In a W2W install, it will show only if the ignition 
input wire is used.

Flashes green 
quickly

START ON command received.

Otherwise, the start signal was not received by the 
module. In a W2W install, it will show only if the ignition 
input wire is used.

D2D and W2W Commands

Flashes orange x 1

LOCK command received.

Flashes orange x 2

UNLOCK command received.

Flashes orange x 3

TRUNK command received.

Flashes orange x 4

AUX1 command received.

Flashes orange x 5

AUX2 command received.

Normal operation.

Flashes

red, red,

orange

Page 14

Содержание 20191108

Страница 1: ...s required for some BMW vehicles which have Key Barrel and Ignition Switch with ribbon cable type 2 and type 3 Features include door locks turn signals windows and sunroof door trigger sensing hood pi...

Страница 2: ...controls function as the customer desires them too A note regarding climate Controls 2015 2014 2013 2012 2011 2010 2009 2008 2007 2006 2005 2004 BMW 1 Series E81 E82 2 2 2 2 2 2 2 2 D D D D D D D D D...

Страница 3: ...PIN 4 Blue PIN 2 Red PIN 3 Violet 4 8 12 Volt Constant Chassis Ground 1 Standard immobilizer interface with TBXKEY TBXKEY are sold SEPARATELY Request an order from Directed using the part numbers lis...

Страница 4: ...White PTS Output Immobilizer Interface see page 3 RF Loop connector Twisted pair in Can Gateway module driver side under dashboard CAN High Yellow Red CAN Low Yellow Brown 3 Tan Black HS CAN High 7 Br...

Страница 5: ...page 3 RF Loop connector Twisted pair in Can Gateway module driver side under dashboard CAN High Yellow Red CAN Low Yellow Brown 3 Tan Black HS CAN High 7 Brown NO Rellay1 10 Orange Red NC Rellay2 8...

Страница 6: ...eries F10 Pin6 White Blue Pin7 Black White Pin8 Orange PTS Wires CanH Yellow Red CanL Yellow Brown Locatingcomponentsinthevehicle CAS Plug CanGateway NOTE Pictures above are representative for BMW 5 S...

Страница 7: ...5 Output 10 Yellow Black KIBMW5 Output P XKD2D65 D2D D2D 5 Violet White AC Tach Output Connect the KIBMW5 Cable to the Key barrel after programming the DB ALL module INSTALLATION TYPE 2 Automatic Tran...

Страница 8: ...ION TYPE 2 Manual Transmission AC Tach Input Ignition Input Ground Ground 12V 12 V Wires are listed by pin numbers This display is not representative of connector pin layouts which are often stacked W...

Страница 9: ...l ribbon cable from ignition key slot Key Slot TYPE 2 Connection Guide for additional module KIBMW5 CAS Connection with DB ALL Connect KIBMW5 Cable between key slot and original plug Secure with cable...

Страница 10: ...switch 1 2 3 4 Wire Side View 3 Green White KIBMW5 Output 4 Red Black KIBMW5 Output 10 Yellow Black KIBMW5 Output P XKD2D65 D2D D2D 5 Violet White AC Tach Output AC Tach Input 6 Gray KIBMW5 Output IN...

Страница 11: ...t RF Loop connector 12 V Ground Ignition Intput Twisted pair in driver kick panel P XKD2D65 7 Gray Black Ignition Status Output 10 Yellow Black KIBMW5 Output D2D D2D wire colours may vary by vehicle m...

Страница 12: ...ke and model of the vehicle the page will refresh to display the compatible firmware 4 In the search result page select one of the available install options config for RSR RXT or Standard install and...

Страница 13: ...the key from the key slot Solid x3 secs Insert Key OFF Remove Key Do NOT press the brake pedal START STOP START STOP E E N N GI 1X 1X PUSH PUSH 1 1 Solid Solid Wait until the LED turns ON solid red a...

Страница 14: ...d 3 th 4 2 Solid Solid Flashes Release 3 Wait 3 seconds until the LED turns ON solid orange and wait 10 more seconds until the LED starts to flash orange and red Release the programming button The LED...

Страница 15: ...atures or options is reached the LED will start flashing again from the first feature or option Once a feature is programmed Other features can be programmed The feature programming can be exited Exit...

Страница 16: ...ashes red x 9 Invalid CAN network The CAN was detected but the ignition message on CAN is not detected Check if the firmare is correct Flashes red x 11 Internal error Report issue to technical support...

Страница 17: ...BE RESPONSIBLE FOR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO ANY CONSEQUENTIAL DAMAGES INCIDENTAL DAMAGES DAMAGES FOR THE LOSS OF TIME LOSS OF EARNINGS COMMERCIAL LOSS LOSS OF ECONOMIC OPPO...

Отзывы: