Rev.: 20191108
Platform: DBALL2
Firmware: BMW03
© 2019 Directed. All rights reserved.
INSTALLATION
-
TYPE
1 (
Automatic Transmission
)
Wires are listed by pin numbers. This display is not representative of connector pin layouts, which are often stacked.
With the exception of the OBII Diagnotistic plug, all connectors are displayed from the wire side.
Remote
Starter
10
Programming button
LED
14
12
2
7: Gray/Black: (+) Ignition Output
1
0
: Yellow/Black: PTS Intput
CAS Plug
Pin 6: White/Blue
Pin 7: Black/White
Pin 8: Orange
(see next page for location)
1: Black/White: Bypass Activation
4
:
Red
/Black: PTS Output
3: Green/White: PTS Output
Immobilizer
Interface
(see page 3)
RF Loop connector
Twisted pair in Can Gateway module,
driver side under dashboard
CAN High:
Yellow/Red
CAN Low:
Yellow/Brown
3: Tan/Black: HS CAN High
7: Brown: NO Rellay1
10: Orange/Red: NC Rellay2
8: Yellow: COM Rellay1
11: Yellow/Red: COM Rellay2
9: Orange/Yellow: NC Rellay1
4: Tan: HS CAN Low
Purple/White
Blue/Red
Blue/Red
Brown/Gray
Brown/Gray
Brown/Black
BCM
CUT
CUT
Located at
brake pedal
Brake switch
1
2
3
4
1
6
7
8
13
26
14
P#: XKD2D65
D2D
D2D
5: Violet/White: (AC) Tach Output
(AC) Tach Input
(-) Handbrake Status Input*
(+) Ignition
In
put
(-) Ground
(-) Ground
(+) 12V
(+) 12 V
Page 4
DBALL/
DBALL2
2: Green/Black:
(-) Handbrake Status Output*
* Handbrake connection is mandatory on Automatic and Manual Transmission cars
You must set “wait to start” feature menu at 10 seconds on your remote starter unit.