https://www.XPOtool.com
Item 62820, 62821
Page 5
The Tool Experts
01 2022-1
Important note!
If the mains cable or the plug have been damaged by external influences, repairs to the cable are pro-
hibited. Repairs may only be carried out by a competent electrician.
Areas of application
This pump is mainly used as a basement pump. When installed in a shaft, this pump provides protection
against flooding. It is also used wherever water needs to be transported from one place to another, for
example at home, in agriculture, horticulture, sanitary work and much more.
Operation requirements
After carefully reading these instructions, you can put the pump into operation. However, note the fol-
lowing things beforehand:
•
The pump is located at the bottom of the shaft.
•
Make sure that the pressure line is properly connected.
•
Check that the electrical connection of 230
V and 50
Hz is present.
•
Check that the socket is in good condition.
•
Any fibre particles accumulated in the pump housing should be removed with a water jet.
•
Make sure that neither water nor humidity can get to the main components.
•
Avoid that the pump runs dry.
Maintenance
•
This waste water pump is an approved and high-quality product that is subject to a strict final
inspection.
•
We recommend regular inspection and maintenance to ensure long equipment life and uninter-
rupted operation.
Caution!
•
Disconnect the power plug before carrying out any maintenance work.
•
If the pump must be transported frequently during operation, it should be cleaned with clear
water after each use.
•
In case of a stationary installation, the function of the float switch should be checked every
3
months.
•
Any fibre particles accumulated in the pump casing should be removed with a water jet.
•
Every 3
months the serrated edge should be cleaned of mud.
•
Remove residues on the float with clear water.
Cleaning the impeller
If excessive sediments accumulate in the pump casing, disassemble the lower part of the pump as
follows:
1.
Loosen the 4
screws from the bottom of the inlet strainer.
2.
Remove the suction strainer from the pump housing.
3.
Clean the impeller with clean water.
Important!
Do not place the pump on the impeller.
4.
Reassemble the pump in reverse order.