If the mains cable or the plug have been damaged by external influences, repairs to the cable are pro-
hibited. Repairs may only be carried out by a competent electrician.

 

 
 

Areas of application

 

 

This pump is mainly used as a basement pump. When installed in a shaft, this pump provides protection 
against flooding. It is also used wherever water needs to be transported from one place to another, for 
example at home, in agriculture, horticulture, sanitary work and much more.

 

 
 

Operation requirements

 

 

After carefully reading these instructions, you can put the pump into operation. However, note the fol-
lowing things beforehand:

 

 

 

The pump is located at the bottom of the shaft.

 

 

Make sure that the pressure line is properly connected.

 

 

Check that the electrical connection of 230

 

V and 50

 

Hz is present.

 

 

Check that the socket is in good condition.

 

 

Any fibre particles accumulated in the pump housing should be removed with a water jet.

 

 

Make sure that neither water nor humidity can get to the main components.

 

 

Avoid that the pump runs dry.

 

 
 

Maintenance

 

 

 

This waste water pump is an approved and high-quality product that is subject to a strict final 
inspection.

 

 

We recommend regular inspection and maintenance to ensure long equipment life and uninter-
rupted operation.

 

 

Caution!

 

 

Disconnect the power plug before carrying out any maintenance work.

 

 

If the pump  must be transported frequently during operation, it should be cleaned with clear 
water after each use.

 

 

In  case  of  a  stationary  installation,  the  function  of  the  float  switch  should  be  checked  every 
3

 

months.

 

 

Any fibre particles accumulated in the pump casing should be removed with a water jet.

 

 

Every 3

 

months the serrated edge should be cleaned of mud.

 

 

Remove residues on the float with clear water.

 

 
 

Cleaning the impeller

 

 

If  excessive  sediments  accumulate  in  the  pump  casing,  disassemble  the  lower  part  of  the  pump  as 
follows:

 

 

1.

 

Loosen the 4

 

screws from the bottom of the inlet strainer.

 

2.

 

Remove the suction strainer from the pump housing.

 

3.

 

Clean the impeller with clean water.

 

Important!

 Do not place the pump on the impeller.

 

4.

 

Reassemble the pump in reverse order.

 

 

 

Содержание 62820

Страница 1: ...ing instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can differ insignificantly Updating the documentation If you have suggestions for improvement or have found any irregularities please contact us ...

Страница 2: ...e our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch Our postal address is WilTec Wildanger Technik GmbH Königsbenden 12 52249 Eschweiler Germany Do you wish to pick goods up Our pick up address is WilTec Wildanger Technik GmbH Königsbenden 28 52249 Eschweiler Germany To shorten...

Страница 3: ...lit Stow away tools and accessories when no longer using them Keep bystanders away from your work area Child proof your workplace by using padlocks and master switches and removing ignition keys When connecting an electrically driven pump all electrical and safety regulations must be fol lowed The pump motor is equipped with an automatic resetting thermal protection and can restart unexpectedly Th...

Страница 4: ...cable or device is damaged in any way If you suspect damage have the device repaired by a professional Only use the pump as described in the instructions Only use accessories recommended by the manufacturer Durability Your submersible pump is intended for the circulation of water with a maximum temperature of 35 This pump must not be used for other liquids especially not for fuels cleaning liquids...

Страница 5: ...th a water jet Make sure that neither water nor humidity can get to the main components Avoid that the pump runs dry Maintenance This waste water pump is an approved and high quality product that is subject to a strict final inspection We recommend regular inspection and maintenance to ensure long equipment life and uninter rupted operation Caution Disconnect the power plug before carrying out any...

Страница 6: ...re that it does not touch the base before the pump switches off Caution Danger of running dry Technical data Item number 62820 62821 Energy supply 230 V 15 Hz Power W 750 1 500 Max flow rate ℓ h 16 000 22 800 Max delivery head m 10 Hose Length m 20 Diameter 50 8 Troubleshooting Error Causes Solution Pump does not start No power supply Check the power supply Floating switch does not switch Move the...

Страница 7: ... a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but must be disposed to a recycling collec tion point for electronic and electrical waste equipment By contributing to the correct disposal of this article you protect the environment and the health of your fellow men Environmen...

Отзывы: