Commissioning
•
If you want to permanently install the device, screw it onto the foundation support with four
screws.
•
If the device is used for the garden pond or for a swimming pool in the garden, it must be par-
ticularly stable and straight so that it cannot overflow, tip over or fall to the ground.
•
Set up the device in a well-ventilated area to avoid the effects of weather. If it is operated inside
a room, make sure that the floor is equipped with a drainage channel or is protected against
leakage.
•
Please check the suction hose before commissioning and make sure that it is airtight. If air is
sucked in, the device can leak, which can cause it to fail.
The suction line must be laid in such a way that no mechanical forces or stresses can
act on it. If dirt builds up in the pipe, install a filter for cleaning and protection.
Caution:
We recommend installing a non-return valve to prevent the system from shutting down
due to dry running.
•
To avoid leaks, all connections of the suction line must be sealed, e.g., with hemp rope or seal-
ing tape.
•
Seal the connection of the metal pipe thread with sealing tape.
•
Have all components of the suction line installed by a specialist.
•
The inside diameter of the suction line must be at least 25
mm; the suction line must not kink
and must be suitable for suction.
•
Since the transport capacity decreases with increasing pipe length, the suction line should be
as short as possible.
•
Lay the suction line with a steady rise to avoid the formation of bubbles.
•
Make sure that enough water is available for the suction line. The connection of the suction
hose must always be completely immersed in the water.
•
All components of the pressure line must be pressure-resistant and may only be installed by
specialists.
Operation
The devices can be permanently connected to the pipeline system (e.g., internal household water sup-
ply). In this case, the device must be connected to the pipe system with the highly flexible hose to avoid
vibrations.
Risk of injury!
If the components cannot withstand the pressure or if the installation is
incorrect, the pressure line may flake off during operation. Danger from leaking liquid!
Risk of electric shock!
Do not operate the device in a damp environment.
Attention:
The device is only connected to the municipal water supply. A toilet or washing ma-
chine may not be used to supply drinking water!
The device may only be operated if the following points are observed:
•
The device may only be connected to an earthed socket. This must be installed, grounded and
checked by a qualified electrician.
•
The power supply and the fuse protection must correspond to the information on the nameplate
and the technical data.
•
The device must be equipped with a protective device with a triggering fault current of less than
30
mA if the device is operated in a swimming pool, in a garden or in a comparable location.
•
In the case of operation outdoors, the electrical connection must be splash-proof. The device
must not be operated in water.