U
SER
M
ANUAL
C
OMMISSIONING
34
4.7
Configuring terminators
Configure the built-in terminators via the rotary switches
(M)
on the
back of the Minilogger Z7. (
Connections and controls)
For the LIN interface, select between internal or external power supply
via the toggle switch
(P)
4.7.1
4x CAN
Position
Resistance
0
Open (∞)
1
2.6 kΩ
2
120 Ω
The channels 3 and 4 have the value
Open
and, therefore, are not
terminated.
4.7.2
1x Dual-FlexRay
Position
Resistance
0
Open (∞)
1
2.6 kΩ
2
90 Ω
There are two variants of the label:
FR-2/1
and
FR-B/A
4.7.3
7x LIN
Position
Power supply
Vi
Internal
Ve
External
Use the internal power supply of the LIN measurement card only if the
connected LIN device uses the Minilogger Z7 voltage as a reference voltage.
Bear in mind that this is not possible when using the Minilogger Z7 in a 24-V
electrical system, for example. In this case, connect the external power
supply port to the corresponding reference voltage.