5.14.7
Create trigger conditions
You use this control element to configure general signal triggers or triggers
of the VIDEO, DiagCCP, DiagXCP and Event interfaces.
The following trigger types are available:
Value compare Raise trigger if a single condition or combined
conditions are met
Signal list
Raise trigger if the Minilogger Z7 detects one of these
signals on the data buses
Value compare:
1 Apply trigger
7 Parenthesise selection
2 Cancel trigger configuration
8 Clear selection
3 Add condition
9 Signal
4 Remove condition
10 Relation
5 Move selection to right
11 Relation type
6 Move selection to left
12 Operator
The following
Relation types
(11)
are available:
Signal value
Number of occurrences of this signal
Time since the last occurrence of this signal (in ms)