before you install
check a few things
115V~60Hz
e
Is the installation location COOL, DRY, LEVEL and away from direct sun.
The water supply valve must provide positive shut off capability and be readily accessible.
Does the unit have a dedicated 115V three prong grounded outlet? (use GFI outdoors)
The Cold Water supply is 1/4” O.D. tube, it should be 50 to 90 F and be between 20 and 80 psi.
(NOTE: as the inlet water temperature increases - production efficiency goes down.)
YOU WILL NEED -
A few simple hand tools:
Pump pliers, adjustable wrench, #2 Phillips head screwdriver, level, razor knife
AND a few hardware items:
Teflon tape or Pipe dope
5/8” I.D. drain hose and hose clamps (if installing a gravity drain model)
1/4” O.D. water supply hose
Air Gap Device and/or Sanitary Trap (depending on your installation).
Water filter with isolation valve
Depending on your installation you will probably require additional site specific plumbing fittings
Water source valve
Water source tub
Drain hose