background image

15 

Part Number

 

18150, E, 02/07/2018 

 

Testing 
 
Test device operation after vehicle has been in storage, before each trip, and at least once per 
week during use. 
 
Single CO Alarm 

Press “Test/Mute” button until Green LED turns on and release.  The alarm will simulate 
2 alarm cycles (2 sets of 4 Beeps, 5 sec. Silence between).  The Red LED will flash once 
every 5 seconds. 

 
Interconnected CO Alarms 

Press and hold the “Test/Mute” button for 60 seconds (1 minute).  The Red LED will 
flash once every 5 seconds on the CO Alarm used to test.  The Red and Green LED will 
flash once every 5 seconds on the interconnected CO Alarms.  All interconnected CO 
Alarms will alarm within 1 minute. 

 
Maintenance 
 
Spaces are to be well ventilated when household cleaning supplies or similar contaminants are 
used.  Avoid spraying liquids directly on alarm. 
 
In the Event of an Alarm 
 

1.

 

Operate reset/silence button 

2.

 

Call your emergency services (fire department or 911). 

3.

 

Immediately move to fresh air – outdoors or by an open door/window.  Check that all 
persons are present.  Do not re-enter the premises or move away from the open 
door/window until emergency services responders have arrived, the premises have 
been aired out and alarm remains in its normal condition. 

4.

 

After following steps 1-3, if your alarm reactivates within a 24-hour period, repeat steps 
1-3 and call a qualified appliance technician to investigate for sources of CO from fuel 
burning equipment and appliances, and inspect for proper operation of the equipment.  
If problems are identified during this inspection, have the equipment serviced 
immediately.  Note any combustion equipment not inspected by the technician and 
consult the manufactures' instructions, or contact the manufacturers directly, for more 
information about CO safety and their equipment. 
 

Nuisance Alarms 
Although the CO Alarm will detect only carbon monoxide in a normal environment, studies have 
found that unusually high concentrations of chemicals and/or vapors may affect the sensor. 
Many of these chemicals are the result of out-gassing in new recreational vehicles.  While these 
chemicals may cause nuisance alarms, levels high enough to create an alarm condition are also 
hazardous.  Treat these “nuisance” alarms as an actual carbon monoxide alarm condition.  
Evacuate and ventilate the area.  Before, during, and immediately after working with any 
chemicals, make sure enough fresh air ventilation is available. 
 

Содержание CMD5-RBI

Страница 1: ...Interconnect CMD5 RDI B RV 12 24 VDC Interconnect Black Housing Owner s Manual Installation Instructions Tested by ETL to UL STD 2034 RV Certified by ETL to CSA 6 19 01 ATTENTION Read and comply with...

Страница 2: ...12 Power Connections CMD5 RD CMD5 RDI CMD5 RD B CMD5 RDI B 13 Interconnect Wiring CMD5 RBI CMD5 RDI CMD5 RBI B CMD5 RDI B 14 Activating Xintex Carbon Monoxide Alarm 14 Testing 15 Single CO Alarm 15 I...

Страница 3: ...ROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE IT WILL NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS IF IN DOUBT CONSULT A MEDICAL PRACTITIONER ANY PERSON WIT...

Страница 4: ...atigue often described as Flu like symptoms Medium exposure Severe throbbing headache drowsiness confusion and fast heart rate Extreme exposure Unconsciousness convulsions cardio respiratory failure a...

Страница 5: ...We Guard Against Carbon Monoxide Carbon monoxide is a by product of combustion CO exists wherever fuels are burned to generate power or heat Recreational vehicles may utilize propane or compressed gas...

Страница 6: ...cted units Limitations This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY source of combustion It is NOT designed to detect smoke fire or any other gas The CO Alarm will not...

Страница 7: ...mA Maximum Current Draw 40 F 40 C to 158 F 70 C 3mA Operating Storage Temperature 40 F 40 C to 158 F 70 C Alarm Points Time Weighted Average TWA Alarm 10 COHb 15min 400 PPM Alarm Horn 85dB 3 05M Dimen...

Страница 8: ...ream The CO Alarm calculates this COHb level as a function of time and determines the appropriate alarm time SEE TABLE 2 Should a very high level of carbon monoxide exist the CO Alarm will alarm in a...

Страница 9: ...ff Off Alarm Off 1 Flash 5 sec 4 Beeps 5 sec Silence Remote Alarm 1 Flash 5 sec 1 Flash 5 sec 4 Beeps 5 sec Silence End of Life Off 1 Flash 5 sec 1 Beep 60 sec CAUTION THE AUDIBLE ALARM CANNOT BE CHEC...

Страница 10: ...MAL CONDITION 4 AFTER FOLLOWING STEPS 1 3 IF ALARM REACTIVATES WITHIN A 24 HOUR PERIOD REPEAT STEPS 1 3 AND CALL A QUALIFIED APPLIANCE TECHNICIAN TO INVESTIGATE FOR SOURCES OF CO FROM FUEL BURNING EQU...

Страница 11: ...g area installation should be at eye level height for convenient monitoring and service Ordinary thermostat height is adequate Ceiling installation is also allowed DO NOT install a CO Alarm near a doo...

Страница 12: ...ole 0 38 9 5mm Max for wired models to accommodate the wires If using a connector on the wires a larger hole may be needed Offset the hole to the side of the Mounting Base with the wire slot as shown...

Страница 13: ...after an alarm indicates the presence of carbon monoxide The phone numbers of emergency services and qualified technicians should be added to the stickers NOTE USE 18 GA WIRES IN ACCORDANCE WITH NATI...

Страница 14: ...RM IS INTENDED TO KEEP ALARM PROTECTED FROM LIQUID SPRAYS THAT MAY BE USED DURING THE INITIAL INSTALLATION PROCESS REMOVE PROTECTIVE COVER BEFORE ACTIVATING Activating Xintex Carbon Monoxide Alarm 1 H...

Страница 15: ...l emergency services responders have arrived the premises have been aired out and alarm remains in its normal condition 4 After following steps 1 3 if your alarm reactivates within a 24 hour period re...

Страница 16: ...Monoxide Alarms Xintex Carbon Monoxide Alarms are not field serviceable Components must be returned to the factory for any repairs Returning Xintex Carbon Monoxide Alarms No product may be returned fo...

Страница 17: ...ment of Fireboy Xintex LLC does not assume the costs of removal and or installation of the product or any other incidental costs of removal and or installation of the product or any other incidental c...

Отзывы: