14
Part Number
18150, E, 02/07/2018
Installation Continued
Interconnect Wiring (CMD5-RBI, CMD5-RDI, CMD5-RBI-B & CMD5-RDI-B)
Brown and Yellow 18 GA wires are provided for interconnecting CO Alarms. Connect the Brown
wires and Yellow wires of up to 10 units to each other.
NOTE:
PROTECTIVE COVER PROVIDED WITH THE ALARM IS INTENDED TO KEEP ALARM PROTECTED
FROM LIQUID SPRAYS THAT MAY BE USED DURING THE INITIAL INSTALLATION PROCESS. REMOVE
PROTECTIVE COVER BEFORE ACTIVATING.
Activating Xintex Carbon Monoxide Alarm
1.
Hold “Test/Mute” button for 10 seconds. The Green LED will turn on.
2.
Press the “Test/Mute” button 5 times. The Green and Red LEDs will flash and the horn
will sound.
The CO Alarm is now activated. The Green LED will flash once every 180 seconds.
+9 to 32 VDC
Battery Ground
Red (+ VDC)
Black (Ground)
Brown (Int -)
Yellow (Int +)
+9 to 32 VDC
Battery Ground