Press CO Alarm against mounting surface and turn clockwise, approximately 25°. 

 

After installation is complete, attach one of the enclosed “Warning” stickers to the wall next to 
the alarm.  Place the other sticker near a source of fresh air where you would gather after an 
alarm indicates the presence of carbon monoxide.  The phone numbers of emergency services 
and qualified technicians should be added to the stickers. 
 

NOTE: 

USE 18 GA WIRES IN ACCORDANCE WITH NATIONAL ELECTRICAL CODES FOR ALL WIRED 
CONNECTIONS. 
 
Power Connections (CMD5-RD, CMD5-RDI, CMD5-RD-B & CMD5-RDI-B) 
 
Red and Black 18 GA wires are provided for connecting to the power source.  Connect the Red 
wire to Power (+).  Connect the Black wire to Ground (-). 

 
 

Red (+ VDC) 

+9 to 32 VDC 

Battery Ground 

Black (Ground) 

Содержание CMD5-RBI

Страница 1: ...Interconnect CMD5 RDI B RV 12 24 VDC Interconnect Black Housing Owner s Manual Installation Instructions Tested by ETL to UL STD 2034 RV Certified by ETL to CSA 6 19 01 ATTENTION Read and comply with...

Страница 2: ...12 Power Connections CMD5 RD CMD5 RDI CMD5 RD B CMD5 RDI B 13 Interconnect Wiring CMD5 RBI CMD5 RDI CMD5 RBI B CMD5 RDI B 14 Activating Xintex Carbon Monoxide Alarm 14 Testing 15 Single CO Alarm 15 I...

Страница 3: ...ROTECT INDIVIDUALS FROM THE ACUTE EFFECTS OF CARBON MONOXIDE EXPOSURE IT WILL NOT FULLY SAFEGUARD INDIVIDUALS WITH SPECIFIC MEDICAL CONDITIONS IF IN DOUBT CONSULT A MEDICAL PRACTITIONER ANY PERSON WIT...

Страница 4: ...atigue often described as Flu like symptoms Medium exposure Severe throbbing headache drowsiness confusion and fast heart rate Extreme exposure Unconsciousness convulsions cardio respiratory failure a...

Страница 5: ...We Guard Against Carbon Monoxide Carbon monoxide is a by product of combustion CO exists wherever fuels are burned to generate power or heat Recreational vehicles may utilize propane or compressed gas...

Страница 6: ...cted units Limitations This carbon monoxide alarm is designed to detect carbon monoxide gas from ANY source of combustion It is NOT designed to detect smoke fire or any other gas The CO Alarm will not...

Страница 7: ...mA Maximum Current Draw 40 F 40 C to 158 F 70 C 3mA Operating Storage Temperature 40 F 40 C to 158 F 70 C Alarm Points Time Weighted Average TWA Alarm 10 COHb 15min 400 PPM Alarm Horn 85dB 3 05M Dimen...

Страница 8: ...ream The CO Alarm calculates this COHb level as a function of time and determines the appropriate alarm time SEE TABLE 2 Should a very high level of carbon monoxide exist the CO Alarm will alarm in a...

Страница 9: ...ff Off Alarm Off 1 Flash 5 sec 4 Beeps 5 sec Silence Remote Alarm 1 Flash 5 sec 1 Flash 5 sec 4 Beeps 5 sec Silence End of Life Off 1 Flash 5 sec 1 Beep 60 sec CAUTION THE AUDIBLE ALARM CANNOT BE CHEC...

Страница 10: ...MAL CONDITION 4 AFTER FOLLOWING STEPS 1 3 IF ALARM REACTIVATES WITHIN A 24 HOUR PERIOD REPEAT STEPS 1 3 AND CALL A QUALIFIED APPLIANCE TECHNICIAN TO INVESTIGATE FOR SOURCES OF CO FROM FUEL BURNING EQU...

Страница 11: ...g area installation should be at eye level height for convenient monitoring and service Ordinary thermostat height is adequate Ceiling installation is also allowed DO NOT install a CO Alarm near a doo...

Страница 12: ...ole 0 38 9 5mm Max for wired models to accommodate the wires If using a connector on the wires a larger hole may be needed Offset the hole to the side of the Mounting Base with the wire slot as shown...

Страница 13: ...after an alarm indicates the presence of carbon monoxide The phone numbers of emergency services and qualified technicians should be added to the stickers NOTE USE 18 GA WIRES IN ACCORDANCE WITH NATI...

Страница 14: ...RM IS INTENDED TO KEEP ALARM PROTECTED FROM LIQUID SPRAYS THAT MAY BE USED DURING THE INITIAL INSTALLATION PROCESS REMOVE PROTECTIVE COVER BEFORE ACTIVATING Activating Xintex Carbon Monoxide Alarm 1 H...

Страница 15: ...l emergency services responders have arrived the premises have been aired out and alarm remains in its normal condition 4 After following steps 1 3 if your alarm reactivates within a 24 hour period re...

Страница 16: ...Monoxide Alarms Xintex Carbon Monoxide Alarms are not field serviceable Components must be returned to the factory for any repairs Returning Xintex Carbon Monoxide Alarms No product may be returned fo...

Страница 17: ...ment of Fireboy Xintex LLC does not assume the costs of removal and or installation of the product or any other incidental costs of removal and or installation of the product or any other incidental c...

Отзывы: