V5 series inverter
81
Fig.
Fig.
Fig.
Fig.4-37
4-37
4-37
4-37
Limits
Limits
Limits
Limits of
of
of
of deviation
deviation
deviation
deviation
Fig.
Fig.
Fig.
Fig.4-38
4-38
4-38
4-38
close-loop
close-loop
close-loop
close-loop preset
preset
preset
preset frequency
frequency
frequency
frequency
0:
0:
0:
0: Positive
Positive
Positive
Positive....
When the reference increases, it will be enabled when the motor speed increase.
1:
1:
1:
1: Negative
Negative
Negative
Negative....
When the reference increases, it will be enabled when the motor speed reduces
Note
:
Define the relationship of reference and speed.
0
:
Stop integral adjustment selection when the frequency reaches upper limit or lower limits
1
:
Continue the integral adjustment selection when the frequency reaches high limit or lower limits
For the system need quick response, cancel the continuouse integral adjustment is recommended.
This function can make the close-loop adjustment enter stable stage quickly.
When the close-loop starts, the frequency will accelerate to the preset value set by P7.16 according to Acc time and the inverter
will running with this freuquency in the holding time set by P7.17, then running according to close-lood character, as shown in
Fig4-38.
Note
Note
Note
Note
:
If the function of close-loop preset frequency is not needed, you can set the preset frequency and holding time as 0.
The two function parameter is used for setting PI threshold and hysteresis of zero-frequency operation.
If you set the frequency as 0 Hz, PI threshold of zero-frequency operation will be disabled.
Fig.
Fig.
Fig.
Fig.4-39
4-39
4-39
4-39
zero-frequency
zero-frequency
zero-frequency
zero-frequency hysteresis
hysteresis
hysteresis
hysteresis
As shown in Fig.4-39
Start process
:
P7.14
P7.14
P7.14
P7.14
Close
Close
Close
Close loop
loop
loop
loop adjustment
adjustment
adjustment
adjustment characteristic
characteristic
characteristic
characteristic
Range
Range
Range
Range
:
0
0
0
0,,,, 1
1
1
1
0
0
0
0
P7.15
P7.15
P7.15
P7.15
Integral
Integral
Integral
Integral adjustment
adjustment
adjustment
adjustment selection
selection
selection
selection
Range
Range
Range
Range
:
0
0
0
0,,,, 1
1
1
1
0
0
0
0
P7.16
P7.16
P7.16
P7.16
Close-loop
Close-loop
Close-loop
Close-loop preset
preset
preset
preset frequency
frequency
frequency
frequency
Range
Range
Range
Range
:
0
0
0
0
-
upper
upper
upper
upper limit
limit
limit
limit of
of
of
of frequency
frequency
frequency
frequency
0.00Hz
0.00Hz
0.00Hz
0.00Hz
P7.17
P7.17
P7.17
P7.17
Holding
Holding
Holding
Holding time
time
time
time of
of
of
of close-loop
close-loop
close-loop
close-loop preset
preset
preset
preset frequency
frequency
frequency
frequency
Range
Range
Range
Range
:
0.0
0.0
0.0
0.0
-
250.0S
250.0S
250.0S
250.0S
0.1S
0.1S
0.1S
0.1S
P7.18
P7.18
P7.18
P7.18
PI
PI
PI
PI Threshold
Threshold
Threshold
Threshold of
of
of
of zero-frequency
zero-frequency
zero-frequency
zero-frequency operation
operation
operation
operation
Range
Range
Range
Range
:
0.00
0.00
0.00
0.00
-
500.0Hz
500.0Hz
500.0Hz
500.0Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz
P7.19
P7.19
P7.19
P7.19
PI
PI
PI
PI hysteresis
hysteresis
hysteresis
hysteresis of
of
of
of zero-frequency
zero-frequency
zero-frequency
zero-frequency operation
operation
operation
operation
Range
Range
Range
Range
:
0.00
0.00
0.00
0.00
-
500.0Hz
500.0Hz
500.0Hz
500.0Hz
0.01Hz
0.01Hz
0.01Hz
0.01Hz