V5 series inverter
31
3-2-3.
3-2-3.
3-2-3.
3-2-3. Fucntion
Fucntion
Fucntion
Fucntion description
description
description
description of
of
of
of LED
LED
LED
LED and
and
and
and indicator
indicator
indicator
indicator
The operation panel consists of 4 bits-8 segments LED, 3 unit indicators and 3 state indicators. The three unit indicators
have 6 different combinations and each combination corresponds to one type of unit while settting parameters.The
relationship between the combination of the indicators and the unit are shown in Fig.3-3.
Fig.
Fig.
Fig.
Fig. 3
3
3
3
-
3
3
3
3 Unit
Unit
Unit
Unit represted
represted
represted
represted by
by
by
by combination
combination
combination
combination of
of
of
of the
the
the
the indicators
indicators
indicators
indicators
3 state indicators locate above the LED display on the operate panel. From left to right are: forward indicator FWD, reverse
indicator REV, alarm indicator ALM. The functions of these indicators are shown in Table3-1
Table
Table
Table
Table 3-1
3-1
3-1
3-1 Functions
Functions
Functions
Functions of
of
of
of status
status
status
status indicators
indicators
indicators
indicators
3-
3-
3-
3-2-4
2-4
2-4
2-4.... Display
Display
Display
Display of
of
of
of the
the
the
the operation
operation
operation
operation panel
panel
panel
panel
The inverter’s operation panel can display four paraters in stopping, editing, fault alarming and running.
1
1
1
1.... Parameters
Parameters
Parameters
Parameters displayed
displayed
displayed
displayed in
in
in
in stopping
stopping
stopping
stopping status
status
status
status
When the inverter stops operation, operation panel displays monitor parameters in stopping status, the normally content is
setting frequency (b-01 monitor parameter). As shown in Fig.3-4,the unit indicator on the top right indicates the unit of this
parameter.
Pressing
key can display other monitor parameters in stopping status circularly (the first seven monitor parameters
in B group are fault displayed value and the other monitor parameters can be defined by function code P3.41 and P3.42,
please refer to Chapter 5 for details).Press
in display status can shift to b-01 which can set frequency, otherwise
the panel will display the last monitor parameter constantly.
Item
Function
D
is
p
la
y
fu
n
ct
io
n
LED display
Display inverter’s current status parameters and setting parameters
S
ta
tu
s
in
d
ic
at
o
rs
FWD
Forward running indicator, inverter outputs positive phase, the
motor will run forward after connecting to the inverter
If FWD and REV indicators all light on,
it means that the inverter are under DC
braking status
REV
Reverse running indicator, inverter outputs negative phase.The
motor will run reverse after connecting to the inverter
ALM
This indicator will light on when the inverter has fault.