11
Servo drive direction
When installing, make the front of the servo drive (the actual installation surface of the
operator) facing the operator and make it vertical to the wall. For the drive with regenerated
resistance at the bottom, please pay attention to the heat dissipation of the mounting surface to
avoid overheating of the drive and causing fire.
Cooling
As shown in the figure above, allow sufficient space around each servo drive for cooling by
cooling fans or natural convection.
Side by side installation
When install servo drives side by side as shown in the figure above, make at least 10mm
between and at least 50mm above and below each servo drive. Install cooling fans above the
servo drives to avoid excessive temperature rise and to maintain even temperature inside the
control panel.
The conditions in the control cabinet