39
voltage
E-005
Regenerative
resistor error
Regenerative resistor is
ineffective
Check the connection of
regenerative resistor
E-006
Module over
temperature
Run with large load for long
time
Reduce the load, and enhance
the cooling system, or check if
the fan is revolving when motor
is ON; cool down the ambient
temperature
E-007
Over current
UVW of drive is short
circuit or the motor is error
Replace the damaged motor;
check the UVW wiring.
E-008
Over speed
Motor speed is too fast,
motor UVW connection is
error
Check if there is other device
that make motor revolve too
fast; check the UVW wiring.
E-009
Analog input
error
Input voltage error when
2-channe analog zero
calibrating
Input correct voltage when zero
calibration for analog
E-010
Position offset
too large
The difference between set
position and actual position
exceeds the limit value
Check if the motor stalled,
decrease the set position speed,
increase offset pulse limit value
P5-05
E-011
Motor UVW is
short circuit
External is short circuit
when fist self-test
Check the UVW wiring of
motor, or replace the damaged
motor
E-012
Motor UVW
current error
Current collection circuit
error
Check the UVW wiring of
motor, or replace the damaged
drive
E-013
Encoder UVW
wire break
Encoder wiring error,
encoder broken, encoder is
Check the wiring of encoder,
and re-connect the encoder after