KCU1250 IBERT Getting Started Guide
13
UG1061 (v2017.4) December 20, 2017
www.xilinx.com
Chapter 1:
KCU1250 IBERT Getting Started Guide
3. Connect J1 connector (USB/UART) on the KCU1250 board to the host computer using
one of the standard-A plug to micro-B plug USB cables provided (
Figure 1-11
).
4. Power up the board by placing SW1 in the ON position.
5. Open a serial communication terminal application on the host computer, for example
“Hyper Terminal”.
6. Connect to the port number associated with the
enhanced COM port
of the Silicon Lab
USB-UART Bridge.
X-Ref Target - Figure 1-11
Figure 1-11:
USB-UART Connector
;
Send Feedback