ChipScope Pro Software and Cores User Guide
127
UG029 (v14.3) October 16, 2012
ChipScope Pro Analyzer Features
data shown in the graphical
Sweep Test Plots
panel. Each row in the table corresponds to
a single sweep test plot.
In 2D Full Scan algorithm mode, the table columns correspond to the following:
•
Enable Plot: shows or hides the plot in the
Sweep Test Plots
panel. Check to show,
uncheck to hide.
•
Plot Name: name of the plot. Click the text field to change plot name.
In 1D Bathtub scan algorithm mode, the table columns correspond to the following:
•
Enable Plot: shows or hides the plot in the
Sweep Test Plots
panel. Check to show,
uncheck to hide.
•
Line Color: color of the line used in the
Sweep Test Plots
panel. Click to select new
color.
•
Plot Name: name of the plot. Click the text field to change plot name.
The remaining columns correspond to the parameter value settings that were used to
create the corresponding sweep test plot. Click the column header to sort the rows in the
sweep test panel.
Note:
One useful sort strategy is to sort the plots from the widest to the lowest UI opening by
clicking the
Opening at the Lowest BER Level
column header.
IBERT 7 Series FPGA GTZ Transceiver Toolbar and Menu Options
IBERT Console Options
The
IBERT Console Options
dialog box allows you to select which columns and rows to
display in the
IBERT
Console. The left panel selects the MGTs by location. Use the
Check
All
and
Uncheck All
buttons to select all or none of the MGTs.
The right panel selects which rows are displayed in the MGT/BERT settings. The
Default
button sets up the Console to display the basic set of rows needed to determine the health
of the channels. The Default rows are MGT Alias, Tile Location, MGT Link Status, PLL
Status, CTLE Tuning, Channel Reset, TX/RX Reset, TX Polarity Invert, TX Error Inject, TX
Diff Output Swing, TX Pre-Cursor, TX Post-Cursor, TX Data Pattern, TXUSRCLK Freq, and
RXUSRCLK Freq.
Import/Export Dialog
In the
Import/Export
dialog box, you can save and recall settings from a specific MGT or
apply the setting of one MGT to others in the design. To import or export settings, select
IBERT_V7GTZ > Import/Export Wizard
or click the
Import/Export Wizard
button in the
toolbar.
The first screen of the wizard chooses the source of the MGT settings, either
MGT
or
File
.
If you select
MGT
, choose among the available MGTs in the combo box. For
File
, click
Browse
and navigate to the settings file.
The second wizard screen is the destination screen. Any combination of the MGTs in the
IBERT design and a file are available. If
File
is enabled, click
Browse
to specify the file
destination.
The third screen is the confirmation screen, summarizing the source and destination(s) for
the settings. Click
Apply
to execute the import or export. This operation cannot be undone.