Command
Meaning
Answer (Payload)
Update
rate
Adapter
version
Fadec
models
RSD
Read Screen Data
ASCII text 32 byte
F
All
All
RCV
Read Current Values
RPM, EGT in ºC, Pump Power, Voltage of Battery, Throttle %
F
All
All
WDU
Data Up Command
OK.
-> Send to the fadec a keypress on the “+” button
-
All
All
WDD
Data Down Command
OK.
-> Send to the fadec a keypress on the “-” button
-
All
All
WMU
Menu Up Command
OK.
-> Send to the fadec a keypress on the “^” button
-
All
All
WMD
Menu Down Command
OK.
-> Send to the fadec a keypress on the “.” button
-
All
All
RAV
Read Adapter version
ASCII version number (ex: 1.0)
F
All
All
REL
Read Engine Limits
Full Power RPM, Idle RPM, Max EGT, Pump Limit, Tank Size ml
S
All
All
Disposal
Electrical equipment marked with the cancelled waste bin symbol must not be discarded in the standard household waste; instead it must be
taken to a suitable specialist disposal system.
In the countries of the EU (European Union) electrical equipment must not be discarded via the normal domestic refuse system (WEEE - Waste
of Electrical and Electronic Equipment,directive 2002/96/EG). You can take unwanted equipment to your nearest local authority waste collection
point or recycling centre. There the equipment will be disposed of correctly and at no cost to you.