BASIC SETUP: 
 

 

The list of measures and commands available in the current software release are 
described in the protocol section.  
 
If the adaptor is going to be used in a flight vehicle and on this application is necessary to 
have the information of fuel flow and remaining tank capacity, due that several fadec 
models don’t support these measures, the adapter itself can calculate these values from 
the data retrieved from the fadec, plus a couple of parameters to be programmed on the 
adapter. This programming is only necessary if you plan to use the fuel flow and tank 
capacity information. 
  
The programming procedure is:   
 
Connect the data terminal to the fadec port on the telemetry adapter trough a “Y” servo 
lead. Connect a battery (4 to 8V) on the other port of the lead to power both devices. 
Connect the battery last, after both devices are already connected. 
 

 

 
The RED led on the adapter will lit, and the data terminal will display  
 
 

Tank capacity:

 using +/- buttons set the tank capacity on your model in 

milliliters. (1Oz=29,6ml) 

Содержание V10

Страница 1: ...e Torrent d en Puig 31 08358 Arenys de Munt Barcelona Catalonia Spain E mail info xicoy com Fax 34 933 969 743 web www xicoy com Xicoy WEEE register number ES004749 Copyright 2014 Xicoy Electronica SL...

Страница 2: ...systems like test bench setups on universities Electrical connections The adapter connects to the ecu trough the supplied 3 wire patch lead and it is powered by the ecu On the other side of the adapte...

Страница 3: ...rieved from the fadec plus a couple of parameters to be programmed on the adapter This programming is only necessary if you plan to use the fuel flow and tank capacity information The programming proc...

Страница 4: ...by the telemetry on landing 3 After landing before to shut down the receiver check the of remaining fuel displayed on the telemetry screen 4 Measure the real quantity of fuel left If you use a regular...

Страница 5: ...ough different commands See table Note that the adapter is continuously retrieving the data from the fadec but due at the nature of the fadec protocols and speed data speed used on different fadec mod...

Страница 6: ...Sync 2Ch Separator 52h R 53h S 44h D 2Ch Separator 0Dh CR last byte The ecu will return two strings First a copy of the command received followed by the data requested In the above example it will re...

Страница 7: ...l REL Read Engine Limits Full Power RPM Idle RPM Max EGT Pump Limit Tank Size ml S All All Disposal Electrical equipment marked with the cancelled waste bin symbol must not be discarded in the standar...