厦 门 四 信 通 信 科 技 有 限 公 司
Xiamen Four-Faith Communication Technology Co., Ltd.
Add:J1-J2,3rd Floor,No.44,GuanRi Road,SoftWare Park,XiaMen,China
7
Zip Code
:
361008
Tel:+86 592-6300320, +86 592-6300321, +86 592-6300322 Fax:+86 592-5912735 http://
www.four-faith.com www.fourfaith.com
2.4 Power
The power range of the router is DC 5
~
35V.
Warning: When we use other power, we should make sure that the power can
supply power above 6W.
We recommend user to use the standard DC 12V/1.5A power.
2.5 Indicator Lights Introduction
The router provides five indicator lights: “Power”, “Online”, “Alarm”, “System”,
“Link/ACT”.
Indicator
Light
State Introduction
Power
Bright
Router is powered on
Dark
Router is powered off
Online
Bright
Router has logged on network
Dark
Router hasn’t logged on network
Alarm
Bright
SIM/UIM card does not work or the signal of the
antenna is week
Dark
Router has not alarm
Sysetm
Twinkle
System works properly
Dark
System does not work
Link/ACT
Dark
The interface of Ethernet hasn’t been connected
Bright /
Twinkle
The interface of Ethernet has been connected
/Communicating
2.6 Reset Button Introduction
The router has a “Reset” button to restore it to its original factory default settings.
When user press the “Reset” button, the router will restore to its original factory
default settings and restart automatically.