Server Bus/Device/Function Number (B/D/F) Information
The server's B/D/F information may change with PCIe card configurations. You can
obtain the B/D/F information of the server using the following methods:
●
SOL serial port information: If serial port information has been collected, search
the keyword RootBusBDF or DeviceBDF in
systemcom.tar
file to query the
B/D/F information of the server.
●
UEFI Shell: You can obtain the B/D/F of the server using the
pci
command. Run
the
help pci
command to obtain the specific usage of the
pci
command.
●
You can obtain the B/D/F of the server using the
pci
command. Run the
help pci
command to obtain the specific usage of the
pci
command.
–
Linux OS: You can obtain the B/D/F information of the server using the
lspci
-vvv
command.
NO TE
If the OS does not support the
lspci
command by default, obtain the
pci-utils
package from the
yum
source and install it to make the OS support the command.
–
Windows OS: After installing the
pci-utils
package, run the
lspci
command
to obtain the B/D/F information of the server.
–
VMware OS: The
lspci
command is supported by default. You can directly
obtain the B/D/F information of the server using the
lspci
command.
5.8 PSUs
●
Supports one PSU or two PSUs.
●
Supports AC or DC PSUs.
●
Supports hot swap.
●
When two PSUs are configured, 1+1 redundancy is supported.
●
PSUs of the same P/N code must be used in a server.
●
Short-circuit protection is provided, and bipolar fuses are provided for PSUs that
support dual live wire input.
●
If you want to use a DC power supply, purchase a DC power supply that meets
the requirements of the safety standards or a DC power supply that has passed
the CCC certification.
●
For details about the optional components, consult the local sales representative
or see "OS and Parts Compatibility" in the
.
Figure 5-65
Positions of PSUs
FusionServer 2288H V7 Server
Technical White Paper
5 Hardware Description
Issue 02 (2023-05-25)
Copyright © xFusion Digital Technologies Co., Ltd.
89