background image

 
 

Copyright © xFusion Digital Technologies Co., Ltd. 2023. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior written
consent of xFusion Digital Technologies Co., Ltd.
 

Trademarks and Permissions

 and other xFusion trademarks are trademarks of xFusion Digital Technologies Co., Ltd.

All other trademarks and trade names mentioned in this document are the property of their respective
holders.
 

Notice

In this document, "xFusion" is used to refer to "xFusion Digital Technologies Co., Ltd." for concise description
and easy understanding, which does not mean that "xFusion" may have any other meaning. Any "xFusion"
mentioned or described hereof may not be understood as any meaning other than "xFusion Digital
Technologies Co., Ltd.", and xFusion Digital Technologies Co., Ltd. shall not bear any liability resulting from
the use of "xFusion".

The purchased products, services and features are stipulated by the contract made between xFusion and
the customer. All or part of the products, services and features described in this document may not be within
the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,
information, and recommendations in this document are provided "AS IS" without warranties, guarantees or
representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the
preparation of this document to ensure accuracy of the contents, but all statements, information, and
recommendations in this document do not constitute a warranty of any kind, express or implied.
 

 

 
 
 
 
 

xFusion Digital Technologies Co., Ltd.

Address:

9th Floor, Building 1, Zensun Boya Square, Longzihu Wisdom Island
Zhengdong New District 450046
Zhengzhou, Henan Province
People's Republic of China

Website:

https://www.xfusion.com

Issue 02 (2023-05-25)

Copyright © xFusion Digital Technologies Co., Ltd.

i

Содержание FusionServer 2288H V7

Страница 1: ...FusionServer 2288H V7 Server Technical White Paper Issue 02 Date 2023 05 25 xFusion Digital Technologies Co Ltd...

Страница 2: ...se of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products services and features described in this docu...

Страница 3: ...Indicates a hazard with a medium risk which if not avoided could result in death or serious injury Indicates a low level hazard which if not avoided could result in minor or moderate injury Indicates...

Страница 4: ...ease Date Change Description 01 2021 06 21 This issue is the first official release FusionServer 2288H V7 Server Technical White Paper About This Document Issue 02 2023 05 25 Copyright xFusion Digital...

Страница 5: ...Compatibility 27 5 4 1 4 DIMM Installation Rules 28 5 4 1 5 Memory Installation Positions 29 5 4 1 6 Memory Protection Technologies 32 5 5 Storage 32 5 5 1 Drive Configurations and Drive Numbering 32...

Страница 6: ...ions 114 6 3 Physical Specifications 116 7 Software and Hardware Compatibility 118 8 Safety Instructions 119 8 1 Security 119 8 2 Maintenance and Warranty 122 9 System Management 124 10 Certifications...

Страница 7: ...58 B 4 P T 158 B 5 U Z 159 C Acronyms and Abbreviations 160 C 1 A E 160 C 2 F J 161 C 3 K O 162 C 4 P T 163 C 5 U Z 165 FusionServer 2288H V7 Server Technical White Paper Contents Issue 02 2023 05 25...

Страница 8: ...rmance computing distributed storage big data processing enterprise or telecom applications and other complex workloads The 2288H V7 features low power consumption high scalability high reliability an...

Страница 9: ...t in drives Supports up to 24 x 2 5 NVMe U 2 drives improving storage density and I O performance The server supports a maximum of 14 standard slots including four built in slots Among the 14 slots up...

Страница 10: ...C or BIOS The NC SI feature is disabled by default NOTE The service network port of the NC SI feature supports the following configurations It can be bound to any network port of the server s OCP 3 0...

Страница 11: ...m Titanium PSUs with different energy efficiency levels The efficiency of the PSUs reaches 96 when the load is 50 Supports active standby power supply and high voltage DC power supply to improve the e...

Страница 12: ...older 7 Air duct NOTE The air duct cannot be installed on a server configured with built in drives or built in cards 8 Intrusion sensor 9 Front drive backplane 10 Left mounting ear plate 11 Front driv...

Страница 13: ...cessor heat sink 17 Processor 18 Cable organizer 19 Mainboard 20 Memory modules 21 TPM TCM 22 OCP 3 0 NIC 23 BMC card FusionServer 2288H V7 Server Technical White Paper 3 Physical Structure Issue 02 2...

Страница 14: ...cessor are connected to the PCIe riser card through PCBs or cables Different PCIe riser cards support PCIe slots of different specifications CPU 1 and CPU 2 each support one OCP 3 0 NIC The PCIe slot...

Страница 15: ...etwork 5 7 I O Expansion 5 8 PSUs 5 9 Fan Modules 5 10 LCD 5 11 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 drive configuration Figure 5 1 Front view FusionServer 2288H V7 Server Technical White P...

Страница 16: ...1 Drive 2 Slide out label plate with an SN label 12 x 3 5 drive configuration Figure 5 3 Front view 1 Drive 2 Slide out label plate with an SN label 24 x 2 5 drive configuration Figure 5 4 Front view...

Страница 17: ...ndicators and buttons on the front panel 1 UID button indicator 2 Health status indicator 3 Power button indicator 4 Fault diagnosis LED 5 FlexIO card 1 presence indicator 6 FlexIO card 2 presence ind...

Страница 18: ...12 x 3 5 drive configuration Figure 5 8 Indicators and buttons on the front panel 1 UID button indicator 2 Health status indicator 3 Power button indicator 4 Fault diagnosis LED 5 FlexIO card 1 presen...

Страница 19: ...ort indicator 25 x 2 5 drive configuration Figure 5 10 Indicators and buttons on the front panel 1 UID button indicator 2 Health status indicator 3 Power button indicator 4 Fault diagnosis LED 5 FlexI...

Страница 20: ...on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly FlexIO card presence indicator Indicates whether the FlexIO card is d...

Страница 21: ...ce is powered on you can hold down this button for 6 seconds to forcibly power off the device When the power indicator is steady yellow you can press this button to power on the device UID button indi...

Страница 22: ...fails or an error is reported when the job is complete Blinking green at short intervals The job is being executed Blinking green at short intervals for 3 seconds and then off The port is disabled St...

Страница 23: ...1 USB 3 0 port 2 iBMC direct connect management port 3 VGA port 24 x 2 5 drive configuration Figure 5 14 Ports on the front panel 1 USB 3 0 port 2 iBMC direct connect management port 3 VGA port 25 x...

Страница 24: ...nly local PCs running Windows 10 are supported To log in to the iBMC from a local PC enter https IP address of the iBMC management network port in the address box of the browser on the local PC Used t...

Страница 25: ...external CD DVD drives an external power supply is required Note The number of ports varies depending on server configuration This table lists the maximum number of ports in different configurations 5...

Страница 26: ...eference only The actual configuration may vary 4 GPU model Figure 5 17 Rear view 1 Slot 1 2 Slot 4 3 Slot 7 4 Slot 9 5 PSU 2 6 PSU 1 7 Optional FlexIO card 2 NOTE The FlexIO card slots support only O...

Страница 27: ...port indicator NOTE Reserved and unavailable currently 4 UID indicator 5 PSU indicator 4 GPU model Figure 5 19 Indicators on the rear panel 1 Data transmission status indicator for the management net...

Страница 28: ...nput is normal and the server is in the standby state The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online Steady g...

Страница 29: ...g the UID button or using the iBMC 5 2 3 Ports Port Positions Server with a drive module or PRM on the rear panel Figure 5 20 Ports on the rear panel 1 Management network port 2 Serial port 3 VGA port...

Страница 30: ...l communication port and its default baud rate is 115 200 bit s VGA port DB15 1 Used to connect a display terminal such as a monitor or KVM USB port USB 3 0 2 Used to connect to a USB 3 0 device NOTIC...

Страница 31: ...supports one or two processors If only one processor is required install it in socket CPU 1 Processors of the same model must be used in a server For details about the optional components consult the...

Страница 32: ...R Single rank 2R Dual rank 4R Quad rank 8R Octal rank 3 Data width on the DRAM x4 4 bit x8 8 bit 4 Type of the memory interface PC5 DDR5 5 Maximum memory speed 4800 MT s 6 Memory latency parameters CL...

Страница 33: ...rimary memory channels first If the primary memory channel is not populated the memory modules in secondary memory channels cannot be used Table 5 5 Memory channels CPU Channel Memory Slot CPU 1 A pri...

Страница 34: ...the following two speed values Memory speed supported by a CPU Maximum operating speed of a memory module The DDR5 memory modules of different types RDIMM and RDIMM 3DS and specifications capacity bi...

Страница 35: ...4800 4800 4800 4800 2DPC 4400 4400 4400 4400 a The maximum number of DDR5 memory modules is based on dual processor configuration The number is halved for a server with only one processor b DIMM per...

Страница 36: ...memory module installation rules when configuring memory modules For details see Memory Configuration Assistant Figure 5 24 Positions of the memory modules FusionServer 2288H V7 Server Technical White...

Страница 37: ...e 5 25 DDR5 memory module installation guidelines 1 processor FusionServer 2288H V7 Server Technical White Paper 5 Hardware Description Issue 02 2023 05 25 Copyright xFusion Digital Technologies Co Lt...

Страница 38: ...e 5 26 DDR5 memory module installation guidelines 2 processors FusionServer 2288H V7 Server Technical White Paper 5 Hardware Description Issue 02 2023 05 25 Copyright xFusion Digital Technologies Co L...

Страница 39: ...le Region ADDDC MR Partial Cache Line Sparing PCLS HBM only 5 5 Storage 5 5 1 Drive Configurations and Drive Numbering 5 5 1 1 8 x 2 5 Drive Pass Through Configurations Drive Configurations Table 5 7...

Страница 40: ...U pass through 8 x 2 5 drive pass through configuration 3 Front drive 8 x 2 5 Slots 0 to 7 support only SATA NVMe drivesa SATA drive PCH pass through NVMe drive CPU pass through 8 x 2 5 drive pass thr...

Страница 41: ...ives For details about the optional components consult the local sales representative or see OS and Parts Compatibility in the Compatibility Checker Drive Numbering NOTICE The drive numbers identified...

Страница 42: ...e iBMC WebUI 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 44 44 45 45 46 46 47 47 Drive numbering of the 8 x 2 5 drive pass through configuration 2 in Table 5 7 FusionServer 2288H V7 Server Technical White Paper 5...

Страница 43: ...Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 44 44 45 45 46 46 47 47 Drive numbering of the 8 x 2 5 drive pass through configuration 3 in Table 5 7 Figure 5 29 Drive numbering Fusi...

Страница 44: ...mbering Table 5 11 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 Drive numbering...

Страница 45: ...2 8 x 2 5 drives 4 x GPU cards in Table 5 7 Figure 5 32 Drive numbering Table 5 13 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card...

Страница 46: ...Rear Drive Built in Drive Drive Management Mode 12 x 2 5 drive 4 x SATA 8 x NVMe pass through configuration 1 Front drive 12 x 2 5 Slots 0 to 3 support only SATA drives Slots 4 and 7 support only SATA...

Страница 47: ...D controller card The PCIe plug in RAID controller card is installed in slot 3 by default NVMe drive CPU pass through 12 x 2 5 drive 4 x SATA 8 x NVMe 4 x GPU card configuration 1 Front drive 12 x 2 5...

Страница 48: ...and Parts Compatibility in the Compatibility Checker Drive numbering NOTICE The drive numbers identified by the RAID controller card vary depending on the cabling of the RAID controller card This sec...

Страница 49: ...and 12 x 2 5 drive 4 x SATA 8 x NVMe 4 x GPU card configuration 2 in Table 5 14 Figure 5 34 Drive numbering Table 5 16 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Id...

Страница 50: ...rations Table 5 17 Drive configurations Configuratio n Front Drive Rear Drive Built in Drive Drive Management Mode 12 x 3 5 drive pass through configuration 1 Front drive 12 x 3 5 Slots 0 to 11 suppor...

Страница 51: ...he PCIe plug in RAID controller card is installed in slot 3 by default NVMe drive CPU pass through 12 x 3 5 drive pass through configuration 3 Front drive 12 x 3 5 Slots 0 to 11 support only SAS SATA...

Страница 52: ...ss through configuration 2 4 x NVMe Front drive 12 x 3 5 Slots 0 to 7 support only SAS SATA drives Slots 8 to 11 support SAS SATA NVMe drives I O module 1 2 x 2 5 a Slots 40 to 41 support only SAS SAT...

Страница 53: ...ified by the RAID controller card vary depending on the cabling of the RAID controller card This section uses the drive numbers identified by a RAID controller card that adopts the default cabling des...

Страница 54: ...8 8 9 9 10 10 11 11 40 40 41 41 44 44 45 45 46 46 47 47 Drive numbering of the 12 x 3 5 drive pass through configuration 2 in Table 5 17 Figure 5 37 Drive numbering FusionServer 2288H V7 Server Techn...

Страница 55: ...2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 40 40 12 41 41 13 42 42 14 43 43 15 44 44 45 45 46 46 47 47 Drive numbering of the 12 x 3 5 drive pass through configuration 3 in Table 5...

Страница 56: ...played on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 FusionServer 2288H V7 Server Technical White Paper 5 Hardware D...

Страница 57: ...6 46 47 47 Drive numbering of the 12 x 3 5 drive pass through configuration 1 4 x NVMe in Table 5 17 Figure 5 39 Drive numbering Table 5 21 Drive numbering Drive No Drive Number Displayed on the iBMC...

Страница 58: ...through configuration 2 4 x NVMe in Table 5 17 Figure 5 40 Drive numbering Table 5 22 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller...

Страница 59: ...10 10Note 11 11 11Note 40 40 12 41 41 13 42 42 14 43 43 15 44 44 45 45 46 46 47 47 Note If the slot is configured with a SAS SATA drive the RAID controller card can manage the drive and allocate a nu...

Страница 60: ...1 2 x 2 5 a Slots 40 to 41 support only SAS SATA drives I O module 2 2 x 3 5 Slots 42 to 43 support only SAS SATA drives I O module 3 4 x 2 5 Slots 44 to 47 support only NVMe drivesb SAS SATA drive 1...

Страница 61: ...e 1 2 x 2 5 is configured with rear 2 x 2 5 drives and a PCIe riser module b NVMe drives are supported when CPU 2 is configured A single CPU server does not support NVMe drives For details about the o...

Страница 62: ...Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 11 11 11 40 40 12 41 41 13 42 42 14 43 43 15 44 44...

Страница 63: ...EXP configuration 2 in Table 5 23 Figure 5 42 Drive numbering Table 5 25 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0 1 1...

Страница 64: ...8 38 14 39 39 15 40 40 16 41 41 17 42 42 18 43 43 19 44 44 20Note 45 45 21Note 46 46 22Note 47 47 23Note Note If the slot is configured with a SAS SATA drive the RAID controller card can manage the dr...

Страница 65: ...ort NVMe drives For details about the optional components consult the local sales representative or see OS and Parts Compatibility in the Compatibility Checker Drive Numbering NOTICE The drive numbers...

Страница 66: ...entified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 0 9 9 1 10 10 2 11 11 3 12 12 4 13 13 5 14 14 6 15 15 7 16 16 0 17 17 1 18 18 2 19 19 3 FusionServer 2288H V7 S...

Страница 67: ...Drive Number Identified by the RAID Controller Card 20 20 4 21 21 5 22 22 6 23 23 7 44 44 45 45 46 46 47 47 FusionServer 2288H V7 Server Technical White Paper 5 Hardware Description Issue 02 2023 05 2...

Страница 68: ...ion 1 8 x SATA 16 x NVMe Front drive 24 x 2 5 Slots 0 to 3 support only SATA drives Slots 4 to 11 support only NVMe drives Slots 12 to 15 support only SATA drives Slots 16 to 23 support only NVMe driv...

Страница 69: ...11 support only NVMe drives Slots 12 to 15 support only SAS SATA drives Slots 16 to 23 support only NVMe drives SAS SATA drive 1 x PCIe plug in RAID controller card The PCIe plug in RAID controller ca...

Страница 70: ...ort only SATA NVMe drives Slots 4 to 11 support only NVMe drives Slots 12 to 15 support only SATA NVMe drives Slots 16 to 23 support only NVMe drives SATA drive PCH pass through NVMe drive CPU pass th...

Страница 71: ...TA drive 1 x PCIe plug in RAID controller card The PCIe plug in RAID controller card is installed in slot 3 by default NVMe drive CPU pass through 24 x 2 5 drive NVMe configuration 5 Front drive 24 x...

Страница 72: ...lt the local sales representative or see OS and Parts Compatibility in the Compatibility Checker Drive numbering NOTICE The drive numbers identified by the RAID controller card vary depending on the c...

Страница 73: ...10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 Drive numbering of the 24 x 2 5 drive NVMe configuration 2 8 x SAS SATA 16 x NVMe in Table 5 28 FusionServer 2288H V7 S...

Страница 74: ...Identified by the RAID Controller Card 0 0 0 1 1 1 2 2 2 3 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 4 13 13 5 14 14 6 15 15 7 16 16 17 17 18 18 19 19 20 20 21 21 22 22 FusionServer 2288H V7 Serv...

Страница 75: ...ing Table 5 31 Drive numbering Drive No Drive Number Displayed on the iBMC WebUI Drive Number Identified by the RAID Controller Card 0 0 0Note 1 1 1Note 2 2 2Note 3 3 3Note 4 4 5 5 6 6 7 7 8 8 9 9 10...

Страница 76: ...ler card can manage the drive and allocate a number to the drive Drive numbering of the 24 x 2 5 drive NVMe configuration 5 in Table 5 28 Figure 5 47 Drive numbering Table 5 32 Drive numbering Drive N...

Страница 77: ...5 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 44 44 45 45 46 46 47 47 Drive numbering of the 24 x 2 5 drive NVMe configuration 6 in Table 5 28 FusionServer 2288H V7 Server Technical White Paper...

Страница 78: ...ebUI Drive Number Identified by the RAID Controller Card 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 10 11 11 12 12 13 13 14 14 15 15 16 16 17 17 18 18 19 19 FusionServer 2288H V7 Server Technical Whit...

Страница 79: ...Drive Number Identified by the RAID Controller Card 20 20 21 21 22 22 23 23 44 44 0 45 45 1 46 46 2 47 47 3 FusionServer 2288H V7 Server Technical White Paper 5 Hardware Description Issue 02 2023 05 2...

Страница 80: ...rivesb SAS SATA drive 1 x PCIe plug in RAID controller card The PCIe plug in RAID controller card is installed in slot 3 by default NVMe drive CPU pass through a The I O module 2 x 2 5 is configured w...

Страница 81: ...2288H V7 Server Maintenance and Service Guide Drive numbering of the 25 x 2 5 drive EXP configuration in Table 5 34 Figure 5 49 Drive numbering Table 5 35 Drive numbering Drive No Drive Number Display...

Страница 82: ...13 13 13 14 14 14 15 15 15 16 16 16 17 17 17 18 18 18 19 19 19 20 20 20 21 21 21 22 22 22 23 23 23 24 24 24 40 40 25 41 41 26 42 42 27 43 43 28 44 44 45 45 46 46 47 47 FusionServer 2288H V7 Server Tec...

Страница 83: ...Off Data is being read or written properly or data on the primary drive is being rebuilt Steady on Blinking blue at 4 Hz The drive is being located Blinking at 1 Hz Blinking red at 1 Hz synchronously...

Страница 84: ...y on blinking Blinking blue at 4 Hz The NVMe drive is being located Blinking at 1 Hz Blinking red at 1 Hz synchronously Data on the NVMe secondary drive is being rebuilt Steady on Off Red steady on Th...

Страница 85: ...in the Compatibility Checker For details about the RAID controller card see the V7 Server RAID Controller Card User Guide 5 6 Network 5 6 1 OCP 3 0 NIC OCP 3 0 NICs provide network expansion capabili...

Страница 86: ...same For details contact technical support 5 7 2 PCIe Slots PCIe Slots Server with a drive module or PCIe riser module on the rear panel Figure 5 52 PCIe slots I O module 1 provides slots 1 2 and 3 I...

Страница 87: ...licable to the Server with a Drive Module or a PCIe Riser Module on the Rear Panel PCIe riser card 1 of I O module 1 2 Provides PCIe slots 1 2 and 3 when installed in I O module 1 Provides PCIe slots...

Страница 88: ...des PCIe slots 2 and 3 when installed in I O module 1 Provides PCIe slots 5 and 6 when installed in I O module 2 Figure 5 57 PCIe riser card 3 PCIe riser card 4 of I O module 1 2 Provides PCIe slot 3...

Страница 89: ...1 of I O module 3 Provides PCIe slots 7 and 8 when installed in I O module 3 Figure 5 60 PCIe riser card 1 PCIe riser card 2 of I O module 3 Provides slots 7 and 8 when one PCIe riser card 2 is instal...

Страница 90: ...n the card slot 4CHP connector J10 Figure 5 62 PCIe riser card 1 PCIe riser card applicable to 4 GPU models PCIe riser card 1 for the rear GPU module For details see 4 GPU built in adapter board when...

Страница 91: ...rd slot 4CHP connector J13 Figure 5 64 PCIe riser card 3 5 7 3 PCIe Slot Description NOTE When CPU 2 is not detected the corresponding PCIe slot is unavailable The PCIe port numbers in table 1 corresp...

Страница 92: ...HHL I O module 2 Slot 4 PCIe 5 0 x16 x 16 CPU 2 Port 1A FHHL Slot 5 PCIe 4 0 x16 x8 CPU 2 Port 2A FHHL Slot 6 PCIe 4 0 x16 x8 CPU 2 Port 2C FHHL PCIe riser card 2 of I O module 1 2 I O module 1 Slot 1...

Страница 93: ...16 x16 CPU 2 Port 0A FHFL PCIe riser card 1 of I O module 3 I O module 3 Slot 7 PCIe 4 0 x16 x16 CPU 2 Port 3A FHHL Slot 8 PCIe 4 0 x16 x16 CPU 2 Port 4A FHHL PCIe riser card 2 of I O module 3 I O mod...

Страница 94: ...ots are compatible with PCIe x16 PCIe x8 PCIe x4 and PCIe x1 cards The bandwidth of the PCIe slot cannot be less than that of the inserted PCIe card The full height full length FHFL PCIe slots are com...

Страница 95: ...d 1 supports the Socket Direct function when it is connected to the two CPUs through high speed cables e The default link bandwidth of FlexIO card 2 is x8 The link bandwidth can be extended to x16 usi...

Страница 96: ...to make the OS support the command Windows OS After installing the pci utils package run the lspci command to obtain the B D F information of the server VMware OS The lspci command is supported by def...

Страница 97: ...ass through configuration supports the LCD Functions The LCD displays the installation status and running status of server components and enables users to set the IP address of the iBMC management net...

Страница 98: ...ns Status Displays the port 80 status serial number component status and component alarms of the server Monitor Displays the current power CPU temperature and inlet temperature of the server FusionSer...

Страница 99: ...information and firmware version Setting Sets the IP address of the iBMC management network port For details about how to use the LCD see FusionServer Rack Server LCD User Guide 5 11 Boards FusionServ...

Страница 100: ...J6066 3 Cell battery holder U6222 4 CPU 2 UBC DD connector UBCDD2 7 J6053 5 OCP 3 0 NIC 2 connector OCP2 CONN J6073 6 RAID M 2 mezzanine card signal connector RAID M 2 J6063 FusionServer 2288H V7 Ser...

Страница 101: ...24 Rear I O module 1 power connector IO1 PWR J6092 25 PCH SATA port C connector PORTC J6100 26 Right mounting ear connector J6060 27 Fan board power connector FAN PWR J6094 28 PCH SATA ports A and B...

Страница 102: ...or PSU1 J6095 51 CPU 2 UBC DD connector UBCDD2 8 J6054 52 Built in drive module power connector INNER PWR J6090 a The reserved connector is temporarily unavailable 5 11 2 Drive Backplane Front Drive B...

Страница 103: ...Mini SAS HD connector PORT B J1 Slots 4 to 7 8 x 2 5 drive pass through backplane This backplane is supported by 8 x 2 5 drive pass through configuration 3 and 8 x 2 5 drive pass through configuratio...

Страница 104: ...UBC2 J2 Slots 2 to 3 4 Backplane signal cable connector HDD_BP J20 5 UBC connector 1 UBC1 J1 Slots 0 to 1 6 Power connector HDD_POWER J21 7 Mini SAS HD connector PORT A J6 Slots 0 to 3 8 Mini SAS HD...

Страница 105: ...lots 8 to 9 3 UBC connector 2 UBC2 J2 Slots 6 to 7 4 UBC connector 1 UBC1 J1 Slots 4 to 5 5 JTAG connector J20 6 Backplane signal connector HDD BP J19 7 Power connector HDD_POWER J21 8 Mini SAS HD con...

Страница 106: ...5 Power connector HDD_POWER J21 6 Backplane signal cable connector HDD BP J19 7 Indicator signal cable connector REAR BP1 J18 8 UBC connector 1 UBC1 J1 Slots 8 to 9 9 UBC connector 2 UBC2 J2 Slots 10...

Страница 107: ...nector HDD BP J1202 6 Low speed signal connector for I O module 2 REAR BP1 J32 7 High speed signal connector for I O module 1 2 REAR PORT IO1 2 J34 8 UBC connector J1 24 x 2 5 drive NVMe backplane All...

Страница 108: ...nector 2 A UBC2 A J1 Slots 0 to 1 11 Backplane signal cable connector HDD BP J40 12 Power connector HDD_POWER J41 13 Mini SAS HD connector PORT A J13 Slots 0 to 3 14 UBC connector 2 D UBC2 D J4 Slots...

Страница 109: ...nector HDD_BP J2 25 x 2 5 drive EXP backplane All drive configurations in 5 5 1 7 25 x 2 5 Drive EXP Configurations support this backplane Figure 5 77 25 x 2 5 drive EXP backplane 1 Low speed signal c...

Страница 110: ...3 5 drive backplane No Connector Managed Drive Slot 1 Mini SAS HD connector PORT B J401 Slots 38 to 39 2 Mini SAS HD connector PORT A J28 Slots 36 to 37 3 Backplane signal cable connector HDD BP J19 4...

Страница 111: ...e connector HDD BP J17 3 Mini SAS HD connector PORT A J28 Management slot for I O module 1 slots 40 to 41 Management slot for I O module 2 slots 42 to 43 2 x 3 5 drive backplane FusionServer 2288H V7...

Страница 112: ...connector PORT A J28 Management slot for I O module 1 slots 40 to 41 Management slot for I O module 2 slots 42 to 43 3 Power connector HDD PWR J21 4 x 2 5 SAS SATA NVMe drive backplane FusionServer 22...

Страница 113: ...01 3 Mini SAS HD connector PORT A J28 Slots 44 to 47 4 UBC connector 2 UBC2 J2 Slots 46 to 47 5 UBC connector 1 UBC1 J1 Slots 44 to 45 4 x 2 5 NVMe drive backplane Figure 5 82 4 x 2 5 drive backplane...

Страница 114: ...J3 2 Reserved and unavailable currently 3 Fan board power connector J10 GND_BLACK J11 POWER_RED 4 Reserved and unavailable currently 5 Reserved and unavailable currently 6 Fan connector FAN1 J7 7 Fan...

Страница 115: ...3 J5 6 UBC connector 4 UBC4 J6 7 UBC connector 2 UBC2 J4 4 x GPU built in adapter board Figure 5 85 4 x GPU built in adapter board 1 Card slot 4CHP connector Riser4 J13 2 Card slot 4CHP connector Rise...

Страница 116: ...3 10 UBC connector 2 UBCDD1 8 2 J4 11 UBC connector 3 UBC1 3 J5 12 UBC connector 4 UBC1 4 J6 13 UBC connector 5 UBC2 3 J8 14 UBC connector 6 UBC2 4 J7 15 UBC connector 7 UBCDD2 8 2 J20 16 UBC connecto...

Страница 117: ...nd eight memory channels per processor Built in PCIe controller supporting PCIe 5 0 and 80 lanes per processor Four UltraPath Interconnect UPI buses between processors providing up to 16 GT s transmis...

Страница 118: ...tion If yes check whether the VMD driver needs to be manually installed and check the installation method When the VMD function is enabled and the latest VMD driver is installed surprise hot swap is s...

Страница 119: ...5 7 2 PCIe Slots and 5 7 3 PCIe Slot Description NOTE The preceding information is for reference only For details see Search Parts in the Compatibility Checker Port Supports a variety of ports Ports...

Страница 120: ...tion supported by the operating system is provided If both the front and rear VGA ports are connected to monitors only the monitor connected to the front VGA port displays information System managemen...

Страница 121: ...thin one year 20 to 75 Maximum change humidity rate 20 per hour Air volume 120 cubic feet per minute CFM to 320 CFM Operating altitude 3050 m 10 006 56 ft When the server configuration complies with A...

Страница 122: ...0 Bels LpAm 44 6 dBA NOTE Actual sound levels generated during operation vary depending on the configuration load and ambient temperature NOTE SSDs and HDDs including NL SAS SAS and SATA cannot be pr...

Страница 123: ...x 31 42 in Figure 6 1 Physical dimensions example a chassis with 3 5 drives NOTE See Figure 6 1 for methods in measuring physical dimensions of the chassis The measuring method for chassis with 3 5 d...

Страница 124: ...rear mounting bars Weight in full configuration Net weight Maximum weight for server with 8 x 2 5 front drives 22 5 kg 49 60 lb Maximum weight for server with 12 x 2 5 front drives 23 5 kg 51 80 lb Ma...

Страница 125: ...tency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact technical support to apply for proof of concept...

Страница 126: ...this device may cause radio interference Human Safety This device is not suitable for use in places where children may be present Only certified or authorized personnel are allowed to install equipme...

Страница 127: ...removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows how to wear an ESD wrist strap a Secure the ESD wrist strap around your wrist b Fasten the strap buckle and en...

Страница 128: ...ers Do not use them for other devices Before operating equipment wear ESD clothes and gloves to prevent electrostatic sensitive devices from being damaged by ESD When moving a device hold the bottom o...

Страница 129: ...riptions in the documentation are for reference only Table 8 1 lists the maximum weight one person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried per...

Страница 130: ...For details on warranty see Warranty FusionServer 2288H V7 Server Technical White Paper 8 Safety Instructions Issue 02 2023 05 25 Copyright xFusion Digital Technologies Co Ltd 123...

Страница 131: ...stable uninterrupted 24 7 system operation by providing the following features The last screenshot and video recording function when the system crashes makes it impossible to analyze the cause of the...

Страница 132: ...onfiguration and upgrades to simplify server installation and configuration Diversified network protocols Supports NTP to improve the device time configuration capability and synchronizes the network...

Страница 133: ...2015 A1 2019 EN IEC 61000 3 2 2019 A1 2021 EN 61000 3 2 2013 A2 2021 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 RoHS EN IEC 63...

Страница 134: ...3 A2 2021 EN 61000 3 2 2014 EN 61000 3 3 2013 EN 55035 2017 A11 2020 CISPR 35 2016 EN 55024 2010 A1 2015 CISPR 24 2010 A1 2015 RoHS BS EN IEC 63000 2018 ErP Commission Regulation EU No 2019 424 China...

Страница 135: ...ss tag 4 Product SN NOTE For details see A 2 Product SN 5 Reserved space for customized label 6 Pressure proof label NOTE This label warns users not to place any objects on top of a rack mounted devic...

Страница 136: ...el NOTE For details see A 4 Nameplate 2 Device name 3 Power supply requirements 4 Vendor information 5 Certification marks A 1 1 2 Certificate Figure A 3 Certificate example FusionServer 2288H V7 Serv...

Страница 137: ...finished server N a spare part 4 0 a value for the reserved digit 5 Year two characters 6 Month one character Digits 1 to 9 indicate January to September respectively Letters A to C indicate October t...

Страница 138: ...A 5 Quick access label example Table A 4 Quick access label description No Description 1 IP address of the iBMC management network port 2 Subnet mask of the iBMC management network port 3 Default iBM...

Страница 139: ...nd QR codes of technical resources The pictures are for reference only For details see the actual product The quick start guide is optional For details see the actual product A 1 3 Chassis Tail Label...

Страница 140: ...years 2001 to 2009 respectively Letters A to H indicate years 2010 to 2017 respectively Letters J to N indicate years 2018 to 2022 respectively Letters P to Y indicate years 2023 to 2032 respectively...

Страница 141: ...ctively Letters P to Y indicate years 2023 to 2032 respectively NOTE The years from 2010 are represented by upper case letters excluding I O and Z because the three letters are similar to the digits 1...

Страница 142: ...ot supporte d A40 GPU cards are not supporte d OCP 3 0 NICs whose rate is greater than 100 Gbit s are not supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the b...

Страница 143: ...Superca pacitors are not supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the built in 4 card module is configur ed Gbit s are not supporte d Superca pacitors...

Страница 144: ...8 x 2 5 drives 4 x GPUs configuratio n All configur ations are supporte d All configur ations are supporte d CPUs with TDP greater than 250 W are not supporte d GPU cards are not supporte d OCP 3 0 NI...

Страница 145: ...ith TDP greater than 250 W are not supporte d A40 GPU cards are not supporte d OCP 3 0 NICs whose rate is greater than 100 Gbit s are not supporte d CPUs with TDP greater than 185 W are not supporte d...

Страница 146: ...5 drives 4 x SAS SATA 8 x NVMe 4 x GPUs configuratio n All configur ations are supporte d All configur ations are supporte d CPUs with TDP greater than 250 W are not supporte d GPU cards are not supp...

Страница 147: ...supporte d The A2 GPU cards are not supporte d when the CPU TDP is higher than 270 W GPU cards are not supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the buil...

Страница 148: ...mperatu re 45 C 113 F Maximum Operating Temperatu re 50 C 118 F configur ed supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the built in 4 x 3 5 drives or 4 ca...

Страница 149: ...e not supporte d The A2 GPU cards are not supporte d when the CPU TDP is higher than 270 W 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the built in 4 x 3 5 drives or...

Страница 150: ...ing Temperatu re 45 C 113 F Maximum Operating Temperatu re 50 C 118 F supporte d 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the built in 4 x 3 5 drives or 4 card mod...

Страница 151: ...not supporte d A16 A40 A100 GPU cards are not supporte d Rear HDDs and NVMe drives are not supporte d OCP 3 0 NICs whose rate is greater than 100 Gbit s are not supporte d CPUs with TDP greater than...

Страница 152: ...e d Rear HDDs and NVMe drives are not supporte d OCP 3 0 NICs whose rate is greater than 100 Gbit s are not supporte d PCIe NICs whose rate is greater than 100 Gbit s are not supporte d CPUs with TDP...

Страница 153: ...in 4 card module is configur ed 6434 64 34H CPUs and CPUs with TDP greater than 250 W are not supporte d GPU cards are not supporte d Rear HDDs and NVMe drives are not supporte d OCP 3 0 NICs whose ra...

Страница 154: ...C 113 F Maximum Operating Temperatu re 50 C 118 F W are not supporte d when the built in 4 card module is configur ed 6434 64 34H CPUs and CPUs with TDP greater than 205 W are not supporte d when the...

Страница 155: ...s configur ed 6434 64 34H CPUs and CPUs with TDP greater than 250 W are not supporte d GPU cards are not supporte d Rear HDDs and NVMe drives are not supporte d OCP 3 0 NICs whose rate is greater than...

Страница 156: ...value When a single fan is faulty the system performance may be affected It is recommended that servers be deployed at an interval of 1U to reduce server noise and improve server energy efficiency Li...

Страница 157: ...perature and the CPU core temperature threshold CPUN N indicates the CPU number The value is 1 or 2 CpuN Margin Difference between the real time CPU temperature and the CPU Tcontrol threshold CPUN N i...

Страница 158: ...2 CPUN FIVRA CPU FIVRA voltage Mainboard or CPU N N indicates the CPU number The value is 1 or 2 CPUN INFAON CPU INFAON voltage CPUN N indicates the CPU number The value is 1 or 2 CPUN VCCFA CPU VCCF...

Страница 159: ...tput current PSUs PS POut PSU output power PSUs PS Temp Maximum internal temperature of the PSU PSUs PS Inlet Temp PSU air inlet temperature PSUs PSN Status PSU fault status PSU N N indicates the PSU...

Страница 160: ...MM N N indicates the DIMM slot number RTC Battery RTC battery status An alarm is generated when the voltage is lower than 1 V RTC battery on the mainboard Power Button Power button pressed state Mainb...

Страница 161: ...the RAID controller card RAID controller card Raid BBU Temp BBU temperature of the RAID controller card Supercapacitor of the RAID controller card PCIE Status PCIe status error PCIe card PCIe OP Temp...

Страница 162: ...emp HBM chip temperature of the GPU card GPU card System Notice Hot restart reminder and fault diagnosis program information collection N A System Error System suspension or restart Check the backgrou...

Страница 163: ...og Full Security log full or events being cleared Host Loss System monitoring software BMA link loss detection ProductID Status Product identification status FusionServer 2288H V7 Server Technical Whi...

Страница 164: ...ment of the devices E ejector lever A part on the panel of a device used to facilitate installation or removal of the device Ethernet A baseband local area network LAN architecture developed by Xerox...

Страница 165: ...e server It seals the front and rear of the chassis to ensure optimal ventilation and electromagnetic compatibility EMC Peripheral Component Interconnect Express PCIe A computer bus PCI which uses the...

Страница 166: ...pecial computer that provides services for clients over a network system event log SEL Event records stored in the system used for subsequent fault diagnosis and system recovery B 5 U Z U U A unit def...

Страница 167: ...B BBU backup battery unit BIOS Basic Input Output System BMC baseboard management controller C CCC China Compulsory Certification CD calendar day CE Conformite Europeenne CIM Common Information Model...

Страница 168: ...rer Association EDB Execute Disable Bit EID enclosure ID EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber...

Страница 169: ...tocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations pe...

Страница 170: ...k Controller Sideband Interface O OCP Open Compute Project C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK Power...

Страница 171: ...single device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Ma...

Страница 172: ...d Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc UPI UltraPath Interconnect USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by I...

Страница 173: ...WSMAN Web Service Management FusionServer 2288H V7 Server Technical White Paper C Acronyms and Abbreviations Issue 02 2023 05 25 Copyright xFusion Digital Technologies Co Ltd 166...