53
Any changes to this table will take effect when the “
Save Terminal Services
” is pressed.
The “Local Serial Interfaces” sets the physical (electrical) interface parameters for the
two user accessible ports as is standard for serial communications. The baud rate can
independently.
3.5.1 Serial Port Binding
By default, the two local serial ports on the Xeta9-E radio are connected, or “bound”,
internally to two of the radio’s four terminal servers. This is indicated in the “Binding”
column of the local serial port settings as TS1 and TS2, respectively. This enables TCP/IP
connections to terminate on the Xeta9-E for serial communications through the local
serial ports as well as the installed RF modules if their protocol setting is set to “Serial”.
However, the built-in terminal servers do not allow serial communications between
local serial ports and the installed RF modules.
If serial data communications are required between the Xeta9-E’s local serial ports and
installed RF modules using the “Serial” protocol, the port’s binding setting can be
changed. For example, setting the binding for the Local/S1 port to “Radio1” will connect
the serial port directly to the radio. The radio will prompt for a restart after this change
before taking affect. Once the binding change is applied, the terminal servers for both
the local serial port and the installed RF module involved will be disabled.
3.5.2 Serial Communications for Xeta9x-E, Eman
The same settings above apply for the Xeta9x-E with the exception that the Xeta9x-E has
only 1 serial port.