Installation
WorkCentre
®
5900 Series
Customer Expectation and Installation Guide
18
Electrical Requirements
Ground Fault Protection is provided which meets Xerox internal safety requirements and exceeds the Industry Standards for Information Technology
Equipment. A single power cord (see above) is required for the WorkCentre 5900 series
Space Requirements/ Service Space Envelope
The dimensions shown below provide the overall service space required, including the space to the nearest obstruction. The dimensions reflect both
typical and hallway installations and are absolute minimums.
Configuration
Machine
Width (A)
mm/inches
Machine
depth (B)
mm/inches
Install Width Required (C)
mm/inches
Install Depth Required (D)
mm/inches
Service Work Space (E)
mm/inches
Left Door Access
Space (F)
mm/inches
Moveable
Fixed
Moveable
Fixed
Moveable
Fixed
Basic machine
without finisher
850 / 33.5
665 / 26.2
2043 / 80.4
3043 / 119.8
1665 / 65.5
2665 / 105
100 / 4
1000 / 39.4
440 / 17
Basic machine
with Office
Finisher
1470 / 57.9
665 / 26.2
2663 / 104.8
3663 / 144.2
1665 / 65.5
2665 / 105
100 / 4
1000 / 39.4
440 / 17
Basic machine
with Office
Finisher and
Booklet Maker
1530 / 60.2
665 / 26.2
2723 / 107.2
3723 / 146.6
1665 / 65.5
2665 / 105
100 / 4
1000 / 39.4
440 / 17
5945/5955
Geographies: Western Hemisphere
Line Option
Sole Use (not required but recommended)
Voltage
110 -127 VAC
Amperage
15 A
Frequency
50/60 Hz, Single Phase
Power Cord
Length
8.5 feet
Receptacle
NEMA part #: 5-15R
Geographies: Eastern Hemisphere
Line Option
Sole Use (not required but recommended)
Voltage
220 – 240 VAC
Amperage
10 A
Frequency
50/60 Hz, Single Phase
Power Cord
Length
2.6 meters
Receptacle
Requires use of a 10 ampere outlet which is
standard in most modern office buildings.
Consult with local service to determine the
country specific receptacle and confirm the
existence of this outlet in the proposed
installation space.
C (Fixed)
D (Fixed)
F
A
B
E
880
mm
C
D
E (Fixed)