Daily Management and Maintenance
3
79
3.3 Print Head Maintenance
3.3.3
Carrying out Calibration
A chart is printed out automatically for calibration.
After replacing a print head or moving the machine, be sure to carry out calibration.
Steps
1.
On the [System Administrator Menu] screen, press [Print Head Maintenance] > [Calibration].
Note
To continue with [Replacing print head], proceed to step 2.. For information on [Replacing print head],
refer to "3.1.4 Replacing a Print Head" (p. 70).
For information on how to display the [System Administrator Menu] screen, refer to
"5.1
System
Administrator Menu Settings Overview
" (p. 104)
.
2.
Select a type of paper to be used for calibration.
Note
Select a roll unit that contains paper of size A0 or larger.
If the correct type of paper is not selected, [Start] can-
not be initiated.
3.
Press [Start].
4.
Press [Yes].
Calibration starts.
5.
Press [Done] to end c
alibration.