Xerox Nuvera
®
100/120/144 EA Digital Production System - Customer Expectations Document
- 46 -
Basic Finishing Module (BFM) and BFM Plus
Dimensions
Basic Finishing Module (BFM)
Width X Depth X Height
32.9” X 28” X 44.5” (835.7mm X 711.2mm X 1130.3mm)
Weight
369 lbs. ( 167.4 kg)
Clearance: Operator
Minimum 38” in front of module
Clearance: Service
Minimum 30” from back wall
Dimensions
Basic Finishing Module Plus (BFM Plus)
Width X Depth X Height
48” X 28” X 44.5” (1220mm X 711.2mm X 1130.3mm)
Weight
494 lbs. ( 167.4 kg)
Clearance: Operator
Minimum 38” in front of module
Clearance: Service
Minimum 30” from back wall
BFM / BFM Plus
Electrical &
Environmental
Minimum
Maximum
Temperature Range
50
°
F (10
°
C)
90
°
F (32.2
°
C)
Humidity Range
15% RH
85% RH
Altitude
0 ft
10,000 ft. (3048m)
Power
200 - 240 VAC
±
10%, 50/ 60 Hz, 8Amps
Media Latitude
BFM / BFM Plus
Stock Weight Range
Uncoated: 16lb. bond to 120lb. index (56 to 250 gsm)
Coated: (90 to 250gsm)
Stock Size Range
7” x 8” to 12” x 18.5” (178 x 203mm to 320mm x 470mm) – See table on following pages
Top Tray Capacity
250 (20 lb. bond / 75 gsm)
Main Stacker
3000 (20 lb. bond / 75 gsm)
Stapler
One or two staples, up to 100 sheets (20 lb. bond / 75 gsm)
System Compatibility
There are two models: the BFM has a top tray (also know as purge tray); the BFM Plus includes a bypass
transport over the stacker
Both the BFM and the BFM Plus may be installed to enable continuous running with unload-while-run.
If one of these modules is the only installed finisher, it must be BFM (with the top tray).
1 or 2 BFM Plus’es may be installed to connect to a downstream FTM to add supported inline DFA finishing.
BFM / BFM Plus Operation
Continuous operation with unload while run is fully supported with a BFM and BFM Plus installation. When a
stacker is full or not ready (e.g. out of staples) the system can auto switch to another available stacker.
Unloads can be configured to occur automatically at stacker limit, at job boundaries, at set or
partition boundaries, or can be initiated manually via the Stacker Unload button or the GUI. A stacker's limit
can be configured to any value between 200 and 3000 and each BFM stacker can be configured
independently and differently. If desired, operators can also program jobs to specific stacker destinations.
Bypass via BFM Plus
Bypass to a downstream finishing device is a capability of the BFM Plus
BFM
BFM Plus