2
2-21
Using the EFI Spectrometer ES-1000 or EFI Densitometer ED-100
If necessary, choose the appropriate COM port for the ES-1000 or ED-100 from the
Port menu.
When you click Start, the Measurements window appears. Directions for measuring
the patches appear in the Status area.
9.
Place the ES-1000 or ED-100 over the specified patch on the Measurement Page,
making sure to center the sample aperture over the patch. Press Measure to take
the measurement.
N
OTE
:
For a more accurate measurement, place several plain sheets of paper beneath
the Measurement Page to block underlying colors from being read by the instrument.
If you have specified multiple clicks per patch, continue pressing Measure to take the
required number of measurements. We recommend that you move the ES-1000 or
ED-100 slightly after each measurement, while keeping the sample aperture within
the patch.