Customer Expectations Setting Guidelines
Xerox DocuColor 40/30 Family Digital Color Production System
14
09/08/99
Version 6.0
ENVIRONMENTAL AND ELECTRICAL REQUIREMENTS
DocuColor 40/30
Environmental
Minimum
Maximum
Temperature (
°
F)
50
°
F (10
°
C)
90
°
F (32
°
C)
Relative Humidity (% RH)
20%
85%
Altitude (Feet above sea level)
None
5,000 Feet
Better performance is achieved when conditions are maintained between 65 - 75
°
F and 25 - 60% RH.
High altitude performance (above 5,000 feet) has not been certified.
Max. Power Consumption
Printing: 2.6 kW or less in full system
8875 BTU / Hr
Standby: 1.8 kW
6143 BTU / Hr
Current loads:
220 VAC assumed
Printing: 11.8 Amps
2.6 kVA (approx.)
Standby: 8.2 Amps
1.8 kVA (approx.)
Electrical Specifications:
Single phase - Two wire plus safety ground
Current Service - 30 Amps (Sole Use)
Frequency - 50/60 Hz
Accessories
Electrical Specifications:
The following power requirements apply to the
Stacker/Stapler, High Capacity Feeder, and the ASF 40 System:
115 VAC for 60Hz or 220 VAC for 50Hz installations (90 to 256VAC in both 50Hz and 60Hz installations.)
Note
:
Power cords are provided with Stacker/Stapler, HCF, ASF 40, and Accumulator/Rotator.
Note
:
DocuColor 40/30, Stacker/Stapler, HCF and ASF 40 and the ASF 40 Accumulator/Rotator require separate power sources.
Note: ASF 40 and ASF 40 Trimmer use the same power source.