27
EN
E 2
The battery has a voltage
between 1.0 and
11.0Volt.
Warning that the battery
is discharged too deeply.
Stays lit for 5 min. Take
no further action and
finish the charging
process.
Warning! If the
battery is frequently
discharged too deeply, the
battery will breakdown
quickly.
E 3
The boost phase (T1) +
the equalize phase (T2) is
longer than 14 hours.
The charging process has
stopped.
Incorrect charging current
- battery capacity ratio.
Consumers are present
during the charging
process, while the
charger is set to 'stand
alone'. Switch off the
consumers or change the
charging program.
Short circuit in battery.
Check the battery.
E 4
The charger is in a
thermical stop.
The charging process will
continue automatically
when the charger has
could down.
- Try to place the charger
in an environment that is
as cool as possible.
- Check whether the
battery has sufficient
ventilation.
E 5
Battery possibly
sulphated.
Monitor this error indi-
cation during the follo-
wing charging sessions. If
this error continues to
occur, have the battery
checked/ replaced.
E 6
Temperature sensor
broken.
Replace the temperature
sensor
The charger is set for
use of the temperature
sensor, but the sensor
isn’t present.
-
- Change the charging
program.
-
- Check the connection