Insulation monitoring
Important!
If this inverter is used in mobile unities, like mobile workplaces,
fire trucks, workmen's huts etc, it is usually difficult to get a good
and reliable safety connection to earth. However, the NEN1010
obligates to make sure that aperson can use an inverter or mobile
generator safely. The standard in NEN 1010 holds that when an
inverter is used, a floating AC-system needs to be created in
combination with an insulation safety device. When a accident
occurs because a insulation safety device isn't mounted in the
system, it has serious consequences. Mount to comply with the
standard, a insulation monitoring device from our ISO-series. For
more info, please visit our website www.xenteq.nl. This standard
applies to all mobile units, with the exception of caravans,
campers, boats and mobile selling vehicles.
I N U S E
Operations
Check that the cables have been mounted correctly. Set the power
switch to “ON” position. The green indicator led
‘inverter’
lights up.
This means that the 230VAC output is available. The inverter is
ready for use.
The red
‘fault’
led indicates an error message. In this case, consult
the chapter ‘protections’ and the trouble shooter. On the rear panel
of the inverter are fuses that protect the input.
A warm housing is normal when the inverter is operating.
A warm housing is normal when the inverter is under load.
If you will not be using the inverter for a significant period (during
winter storage for example), we recommend disconnecting it from
the battery.