PAGE 16
OUTPUT POWER ADJUSTMENT PROCEDURES
NOTE
FAMILIARIZE YOURSELF WITH THE LOCATION AND IDENTIFICATION OF THE COMPONENTS OF THIS SYSTEM AND
ALSO THE NORMAL OPERATION OF THE SYSTEM BEFORE ATTEMPTING ANY ADJUSTMENT OR SERVICE.
NOTE
COMPLETELY READ THROUGH AND HAVE A GOOD UNDERSTANDING OF THE PROCEDURES BEFORE
ATTEMPTING TO SERVICE THIS SYSTEM. FAILURE TO DO SO MAY RESULT IN FATAL INJURY OR EQUIPMENT
DAMAGE.
WARNING
THIS SYSTEM USES TWO SOURCES OF POWER. DISCONNECT BOTH POWER SOURCES BEFORE SERVICING THIS
EQUIPMENT.
WARNING
THIS SYSTEM MAY BE UNDER THE CONTROL OF AN AUTOMATIC TIMING SYSTEM AND MAY START AT ANY TIME
WHEN THE NORMAL / SERVICE SELECTOR SWITCH IS IN THE NORMAL POSITION.
EQUIPMENT REQUIRED
1. WRENCH 3/8
ADJUSTMENT INSTRUCTIONS
1. REMOVE LOWER ACCESS COVER FROM THE FRONT OF THE BASE ENCLOSURE BY REMOVING THE 6
SCREWS ALONG THE SIDES OF THE PANEL WITH A 3/8 WRENCH.
2. NOTE THE LOCATION AND SETTINGS OF THE POWER SUPPLY POWER ADJUSTMENT SWITCHES.
3. IF THE SYSTEM IS TO BE ADJUSTED WITHOUT THE CONTROL TIMING CIRCUIT ENERGIZED SET THE MAIN
POWER SWITCH TO THE OFF POSITION AND SET THE NORMAL / SERVICE SELECTOR SWITCH TO THE SERVICE
POSITION.
4. SET THE MAIN POWER SWITCH TO THE ON POSITION. THE UNIT COOLING SYSTEM SHOULD START
IMMEDIATELY, AND THE LAMP SHOULD STRIKE AFTER A SEVERAL SECOND DELAY. IF NOTHING HAPPENS
AND THE SELECTOR SWITCH IS SET PER STEP 2 CHECK THE MAIN 3 PHASE POWER SUPPLING THIS SYSTEM IN
ALL LIKELIHOOD THE MAIN POWER HAS BEEN TURNED OFF AT THE SOURCE.
5. USING THE METERS ON THE CONTROL PANEL MEASURE THE OUTPUT VOLTAGE AND CURRENT OF THE
POWER SUPPLY.
6. CALCULATE THE OUTPUT POWER USING THE FORMULA (VOLTS) X (AMPS) = (WATTS). IF THE POWER LEVEL IS
OVER 10500 WATTS IMMEDIATELY TURN OFF THE LIGHT AND GO TO STEP 8.
7. ALLOW THE LIGHT TO RUN AT LEAST 10 MINUTES BEFORE MAKING ANY ADJUSTMENTS.
8. TURN OFF THE LIGHT USING THE MAIN POWER SWITCH ON THE CONTROL PANEL. THE COOLING SYSTEM
WILL CONTINUE TO RUN FOR AT LEAST 30 MINUTES AFTER THE POWER IS TURNED OFF. DO NOT BE
CONCERNED. THE POWER TO THE POWER SUPPLY ADJUSTMENT SWITCHES HAS BEEN DISCONNECTED BY
THE UNIT’S MAIN POWER CONTACTOR.