52
Data Compare: This function is applicable to most memory chips and SCM chips.
Data in the buffer and the chip will be compared byte by byte. The different data and
the address in the buffer and the chip memory will be recorded and saved in file in the
Bin directory. The file name and path will be displayed in the Operation Info screen.
A data comparison example:
Compare result in file:
C:\SP3000U\BIN\27256.CMP
The file format is shown in the following:
Title : SUPERPRO Data Compare Result file.
Displacement Buffer address Chip Data Buffer Data
-----------------------------------------------------------
000000D0 04 12(EPROM)
000000D1 00 34(EPROM)
000000D2 00 56(EPROM)
000000D3 00 78(EPROM)
000000D4 00 90(EPROM)
000004A5 00 AA(EPROM)
000004A6 00 BB(EPROM)
000004A7 00 CC(EPROM)
Displacement Buffer address
Chip Data
Buffer Data
Note: If there are many buffers, the buffer names (such as EPROM) will be added.
However, most buffers do not have the names.
If a PLD device with a U-Field is selected, the Operation Option Bar will look like
the following:
U.E.S.: Edit user electronic signature. This content may be changed during reading
the device or loading files. Users can check and edit U.E.S. (two display methods,
Hex and ASCII).