The  XBody  Training  Suit  is  intended  as  a  training  and  exercise  appliance  for  muscle 
conditioning  in  conjunction  with  the  XBody  Training®  functioning  on  the  basis  of  electronic 
stimulations applied to various muscle groups through the use of electrodes contained in the training 
suit. Follow the instructions in this manual to assure proper training and safety operation to the user. 
In addition if you connect the Training Suit to an EMS device all contraindications and safety regulations 
of the EMS device shall be taken into account. Be aware that improper use of this equipment can cause 
injury. XBody Hungary LLC does not take the responsibility where user negligence or improper use of 
the equipment has occurred. 

3.1

 

Where never to apply the electrodes

 

 

On the head or any area of the face. The effects of stimulation of the brain are unknown. 

 

On the neck or any area of the throat. Severe spasm of the muscles may occur and the 
contractions may be strong enough to close the airway or cause difficulty in breathing. 

 

Electrodes used for electrical stimulation should not be applied near the thorax because the 
introduction of electrical current on this part of the body increases the risk of cardiac 
fibrillation. 

 

On, or in the vicinity of skin lesions or eruptions of any kind. 

 

Over the abdominal region during menstruation periods. 

 

On skin areas lacking of normal sensation. 

 

It is not recommended to change the locations or modify the containment of the 
electrodes within the training suit at all! 

3.2

 

Safety regulations 

 

Electrodes should be applied only to normal, intact, clean skin. Electrodes should not be 
applied over open wounds or over swollen, infected, or inflamed areas or skin eruptions 
(e.g., phlebitis, thrombophlebitis, varicose veins, etc.). 

 

The electrodes must be connected to the muscle groups in their original place in the training 
suit and they must be fixed with Velcro straps. 

 

Electrodes must be slicked to the body with their whole surface. A partial connection can 
increase the current density and it can result in pain or skin irritation. 

 

Only undamaged electrode cables are permitted to be connected to the training suit. 

 

Do not unplug wires or cables during training. You must stop or pause the training if you 
want to do so. 

 

Do not connect or disconnect electrodes during the training. You must stop or pause the 
training if you want to do so. 

3.3

 

Precautions 

 

Some persons may experience skin irritation or hypersensitivity due to the electrical 
stimulation.  

 

This device should only be used with the original accessories (cable whip, etc.) and together 
with an XBody EMS machine to assure safe and efficient trainings. 

 

Never set damaged suit in operation. In case you observe damage, unusual smell or fuming 
immediately inform the helpdesk of XBody Hungary LLC. 

 

Do not try to repair or manipulate the suit anyways because the warranty is left off in case of 
unintended use. 

Содержание TRAINING SUIT

Страница 1: ...XBODY TRAINING SUIT USER MANUAL...

Страница 2: ...4 2 Sizes of training suits and other accessories 7 4 3 Preparing the suit for use 8 4 4 Cable and Electrode Installation 9 4 5 Review of the cabling and electrode installation process 21 4 6 Suiting...

Страница 3: ...tion about your XBody Training Suit and its accessories Before using the suit please make sure that you have familiarized yourself with the contents of this manual by reading it carefully In addition...

Страница 4: ...rt are present and check to assure that no damage occurred during the shipment In case something is missing or any accessories or the machine itself have been damaged during the delivery please contac...

Страница 5: ...nstruation periods On skin areas lacking of normal sensation It is not recommended to change the locations or modify the containment of the electrodes within the training suit at all 3 2 Safety regula...

Страница 6: ...at are not included in the user manual 3 4 Training advices Maintenance can be done neither by the client nor the trainer see the Maintenance section for details Although the electrodes do not provide...

Страница 7: ...perly The flexible bands do not have any negative impact on movements during training Bi elastic construction ensures the retention of the suit architecture Electrodes can be installed easily into the...

Страница 8: ...s of the shoulder These electrode uses an L formed electrode which can be ordered additionally from XBody Hungary LLC Shoulder electrodes 4 3 Preparing the suit for use The suits are packed in the pac...

Страница 9: ...or the spiral cable The two long wire sets are for the vest and the two shorter wire sets are for the pants There are three types of electrodes 4 D formed 8 Square formed and 4 L formed are necessary...

Страница 10: ...piral cable connector of the cable whip in the socket at the bottom of the vest as shown in the photo Step 2 Lace up the longer cables from the bottom into the vest by doubling the longer cables and p...

Страница 11: ...Manual Version 1 1 Page 11 29 Step 3 Pull the cables of the vest through the hole Step 4 The pants have a shorter wire set for which the same method shall be followed for lacing the cables into the p...

Страница 12: ...5 Pull the cables of the pants though the hole Step 6 Layout the long wire set in the interior of the vest as shown Each wire shall end at the indicated electrode placement area The wires are color c...

Страница 13: ...les in their designed positions with the Velcro straps Step 8 Use the loops provided to route and lead the wires to the corresponding electrode positions with respect to the color coding of the wires...

Страница 14: ...wo very long wires one on each side of the vest Route these through their exit port at the upper left and upper right corners of the vest Step 10 Use the Velcro straps to secure the short cabling in t...

Страница 15: ...1 Page 15 29 Step 11 Route the wires according to the color coding through the loops in the pants in the same manner as described for the vest Step 12 The suit is properly prepared for electrode plac...

Страница 16: ...med electrodes are required Two for the sides of the vest orange and two in the back of the vest white Four L formed electrodes are required Each is for the top of the vest red and blue Note If a clie...

Страница 17: ...fastener place the connected electrode over the stitching which defines the shape of the electrode and attach it to its place with the Velcro attachment interface Step 15 Complete the installation of...

Страница 18: ...es Connect the snap fastener of each wire with the male attachment point of the electrode on the Velcro strap side of the containment Step 17 The blue electrode shall be in a cover with three Velcro a...

Страница 19: ...electrode is properly placed and installed in the upper left side of the vest while the upper right side of the vest is just prior to installation Step 19 All L formed electrodes are shown properly in...

Страница 20: ...connection depending upon how the trainer would like to stimulate this muscle group Be sure that the orientation of the placement of the electrodes must be the same on both sides This step shows the...

Страница 21: ...the flexors and extensors in the pants o D formed electrodes Install 2 pieces for the two sides of the vest abdomen Install 2 pieces for the backside of the vest o L formed electrodes Install 2 piece...

Страница 22: ...hown above the belts can be fastened In case the client fastens the belts for himself herself check the belts before starting the training to be certain that it fits the whole body This check is indis...

Страница 23: ...User Manual Version 1 1 Page 23 29 The following figures show a correctly assambled suit Front and back view of a correctly assembled suit Side view of a correctly assembled suit...

Страница 24: ...and agitation in a cold washing cycle without softener Roll up and store the cables carefully The electrodes can be disinfected using a non granular disinfecting solution e g 30 70 alcohol and di wat...

Страница 25: ...and cannot be prevented Damage due to unprofessional use can be prevented The user is responsible to use the suit professionally to avoid damage 5 2 Electrodes The electrodes are designed to be easily...

Страница 26: ...he date of buying and the serial number Please wrap the product as a fragile one Damage caused during the delivery is the sender s responsibility Send the package to the following address XBody Hungar...

Страница 27: ...the machines Warranty period for the training suits and cables are 6 months Warranty period for the electrodes are 60 months The damages of the accessories do not mean the replacement of the machine...

Страница 28: ...forms with all EU directives or EU regulations that apply to it Old machines must not be thrown among the domestic waste Please follow the rules for the waste collection in that area or get into conta...

Страница 29: ...strap system Electrodes Pieces per suit 18 All electrodes are deemed reusable Surface L formed 99 09 cm2 Surface short arm electrode 136 42 cm2 Surface square formed electrode 152 62 cm2 Surface long...

Отзывы: