2.2)   Stimulation Mode

DEFAULT: 

Hybrid RF

Options: 

Hybrid RF, Square Wave

Use the 

Wheel

 to navigate to 

STIMULATION MODE

. Press 

enter

 to select.

Hybrid RF Mode

The “      “ indicator in the main window tells the user that the device is in 
Hybrid RF Mode.

2)  Setting up Device Defaults

Access the 

Setup Menu

 by pressing 

and holding the 

Menu/Pulse Width 

Button

. The setup menu allows the 

user to customise all the default 

 

settings.

2.1)   Languages

DEFAULT: 

English

Use the 

Wheel

 to navigate to 

LANGUAGE

. Press 

enter

 to select.

To select another default language, use the Wheel to 

 

navigate to the preferred language. Press 

enter

 to select. 

The radio button next to the selected language will show 

that it is activated. To exit scroll down the menu to 

EXIT 

MENU

 and press 

enter

.

A conformation screen will show your selection, with an   

option to 

ACCEPT

YES

 will take you back to the main 

Setup Menu

.

NO

 will take you to the previous screen.

The 

radio button

 next to 

Hybrid RF Mode

 will show that 

it is 

activated

 

To exit scroll down the menu to 

EXIT MENU

 and press  

enter

.

The 

radio button

 next to 

Square Wave Mode 

will show 

that it is 

activated

To exit scroll down the menu to 

EXIT MENU

 and press  

enter

.

A conformation screen will show your selection, with an   

option to 

ACCEPT

YES

 will take you back to the main 

Setup Menu

.

NO

 will take you to the previous screen.

A conformation screen will show your selection, with an   

option to 

ACCEPT

YES

 will take you back to the main 

Setup Menu

.

NO

 will take you to the previous screen.

Square Wave Mode

The “      “ indicator in the main window tells the user that the device is in 
Square Wave Mode.

Separate collection 
for electrical and 
electronic equipment
(Applicable to EU 
community only)

Temperature 
limit

Humidity 
limitation

5

Содержание STIMPOD MMS460

Страница 1: ...PRODUCT CODE XT 46006 EN XM400 31A04 07...

Страница 2: ...i...

Страница 3: ...be observed to verify normal operation in the configuration in which it will be used The patient should avoid contact with metallic objects that are grounded produce an electrical conductive connectio...

Страница 4: ...e stimulators are a symptomatic treatment and as such suppresses the sensation of pain that would otherwise serve as a protective mechanism Effectiveness is highly dependent upon patient selection by...

Страница 5: ...healthcare pro fessional only This equipment system may cause radio interference or disrupt the operation of nearby equipment It may be necessary to take mitigation measures such as re orienting or re...

Страница 6: ...e d 1 2 80 MHz to 800 MHz d 2 3 800 MHz to 2 5 GHz where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separatio...

Страница 7: ...pplicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 800 MHz the separa...

Страница 8: ...er 4 1 8 Shutdown 4 1 9 Symbols on device battery clip 4 2 Setting up Device Defaults 5 2 1 Languages 5 2 2 Stimulation Mode 5 2 3 Pulse Width Options 6 2 4 Stimulating Frequency 6 2 5 Countdown Timer...

Страница 9: ...n those supplied with the STIMPOD NMS460 may result in serious injury NOTE Standard ECG Electrodes can be used for the anode Such ECG electrodes need to conform to ANSI AAMI EC12 on disposable ECG ele...

Страница 10: ...s to Enter in setup menu Stimulating LED indicator Flashing Green Stimulus delivered Flashing Red Open Circuit detected Menu Pulse Width Button Press to toggle between Pulse Widths Press and hold to a...

Страница 11: ...too high higher than 13 kOhm This is most likely caused by a poor grounding electrode skin connection Pause This warning informs the user that the PAUSE button was pressed The STIMPOD NMS460 will pau...

Страница 12: ...ircuit Detection A few milliseconds prior to the actual stimulation an impedance measurement is made to detect whether the connection between the STIMPOD NMS460 and the patient comprises a closed circ...

Страница 13: ...croll down the menu to EXIT MENU and press enter A conformation screen will show your selection with an option to ACCEPT YES will take you back to the main Setup Menu NO will take you to the previous...

Страница 14: ...ter A confirmation screen will show your selection with an option to ACCEPT YES will take you back to the main Setup Menu NO will take you back to the previous screen 2 5 Countdown Timer DEFAULT 10 mi...

Страница 15: ...rstheusertheoptiontoenteruserinformation Twolinesof20 characters each may be entered This user information will be displayed for two seconds when unit is switched on as per example Use the Wheel to na...

Страница 16: ...ld flash GREEN and if sound is enabled in the menu a beep should be heard each time a stimulus is delivered Stimulus should occur at the set frequency 1 2 or 5 Hz Use the adjusting wheel and slowly in...

Страница 17: ...er Consumption 17mA Weight 130g Dimensions 145mm x 90mm x 30mm Operating Temperature 10 40 Celsius Storage and Transport Temperature 0 50 Celsius Operating Humidity 90 Relative Humidity 3 3 Cleaning a...

Страница 18: ...e NMS 460 PERIPHERAL NERVE STIMULATOR ONLY XT 46000 No cables or accessories NMS 460 PERIPHERAL NERVE STIMULATOR KIT XT 46001 Including Mapping Probe Carry Case IFU NERVE MAPPING CABLE XT 46003 CARRY...

Страница 19: ...11...

Страница 20: ...Unit 102 The Tannery Industrial Park 309 Derdepoort Rd Silverton Pretoria South Africa 0184 Tel 27 0 12 743 5959 Fax 27 0 86 547 0026 E mail support xavant com Web www xavant com...

Отзывы: