Monitoring Operation
2–12
975-0240-01-01
Pressing the down arrow button from the XW Inverter/Charger Home screen
displays the Home screens for other XW Inverter/Chargers and other Xanbus-
enabled devices in the system.
Figure 2-6
XW Inverter/Charger Home Screen
setup
system
XW6048 00:Home
Invert
-26.4A 51.9V
1250W
0.0V 0W
Top Line: Device name and number
Line 1: Inverter/charger status
Line 2: Battery current (in + or out –) and voltage
Line 3: Power supplied to loads
Line 4: AC in status
“Setup” arrow indicates the Enter
button. Pressing Enter displays the
XW Inverter/Charger setup menu.
“System” arrow indicates the Exit
button. Pressing Exit displays the
System Home screen.
Table 2-1
XW Inverter/Charger Home Screen States
XW Inverter/
Charger Status
Displayed When...
Invert
The XW Inverter/Charger is supplying power to loads by inverting power from the batteries. AC
input from the utility or generator is absent or out of nominal range.
Qualifying AC
The XW Inverter/Charger is determining if AC input is within a usable voltage and frequency
range. “Qualifying AC” is also displayed when the XW Inverter/Charger is awaiting application
of AC power or a command to enable invert mode.
Charging
The XW Inverter/Charger is charging the batteries from qualified AC input from the utility grid
or a generator. The charge state is in transition to either Bulk, Absorption, Float or Equalize. AC
input is also passed through to the load while charging.
Bulk
The XW Inverter/Charger is bulk charging the batteries from qualified AC input from the utility
grid or a generator. AC input is also passed through to the load while bulk charging.
Absorption
The XW Inverter/Charger is absorption charging the batteries from qualified AC input from the
utility grid or a generator. AC input is also passed through to the load while absorption charging.
ABS Finish
The XW Inverter/Charger has completed the absorption stage and is waiting for other chargers
in the system to complete absorption. This status can occur only when there is another device (an
inverter/charger or charge controller) also charging the battery.
Float
The XW Inverter/Charger is float charging the batteries from qualified AC input from the utility
grid or a generator. The XW Inverter/Charger is set for three-stage charging. AC input is also
passed through to the load while float charging.
CHG Finish
The XW Inverter/Charger has completed charging or the charge cycle has been interrupted and
is transitioning to the next state. This stage last about one minute, while the battery is allowed to
settle. The delay keeps the inverter/charger from unnecessarily transitioning to Grid Support (if
enabled) after a charge cycle.