Troubleshooting
975-1038-01-01
51
Symptom
The XPLORE Charger appears to be taking too long to charge
battery. Ready indicator LED does not illuminate after 24 hours of
charging.
Possible Cause
Solution
Battery capacity is too high
for the XPLORE Charger
model.
Use a higher capacity charger.
Load connected to battery is
draining charge current so
that battery does not
recharge.
Disconnect all loads or switch
loads off.
Battery has a damaged cell
or has reached the end of
its useful life.
Replace battery.
The Max Charging Current
setting is too low for the
battery capacity.
Increase the Max Charging
Current setting.
Symptom
The XPLORE Charger appears to have quickly charged the
battery. Ready indicator LED illuminates sooner than expected.
Possible Cause
Solution
Battery capacity is too low
for the XPLORE Charger
model.
Reduce the Maximum Charge
Current setting.
Battery has a damaged cell
or has reached the end of
its useful life.
Replace battery.