975-1038-01-01
25
The XPLORE Charger has a ground/earth lug on the side of the
unit as shown in
. Follow the guidelines in
to connect the charger’s chassis to the
ground.
Figure 10 DC equipment ground/earth connection
A
A
DC equipment grounding lug (M6)
DC Grounding (Earthing) Locations
NOTE
: For simplicity, all references to ground is also a reference
to earth.
You must connect the DC equipment ground lug to a grounding
point—usually the vessel's chassis—using recommended copper
wire size (if insulated then green insulation with or without one or
more yellow stripes) or larger.
Make sure to tighten the bolt on the ground lug to a torque of 23 in-
lb (2.6 N-m) of force. Apply an anti-corrosion compound to the
copper wire prior to connecting to the ground lug.
For recommended equipment ground cable size, see below.
Application
Minimum equipment ground cable size
(Stranded copper cable is required)
Marine
a
No. 4 AWG (25mm
2
)
NOTE
: There are no restrictions on length for the equipment
ground cable but try to make it as short as practical to a secure
chassis connection. In general, the equipment ground cable size
must not be smaller than one gauge than the supply cable.
Table 4 DC equipment ground cable size
a
Based specifically on on ABYC E-11 § 11.16 2. IEC standards may be similar or different. Check with
your local standards.
Содержание XPLORE 120A 12V
Страница 1: ...XPLORE 120A 12V Battery Charger Owner s Guide Model XPLORE 120 12 Battery Charger 819 0120 12...
Страница 12: ...This page is intentionally left blank 2...
Страница 18: ...This page is intentionally left blank 2...
Страница 24: ...This page is intentionally left blank 2...
Страница 60: ...This page is intentionally left blank 2...
Страница 72: ...975 1038 01 01 Rev C 31021 http www xantrex com 1 800 670 0707 1 408 987 6030 Printed in...