Calibration
Battery Charging
86
Operating Manual for XKW 3kW Series Power Supply
Battery Charging
When using this power supply to charge a battery, take the following precautions to
prevent damage to the supply and/or the battery
in case the overvoltage protection
(OVP) circuit is activated
.
1. Select a diode rated to handle the required charging current and voltage. Use the
following table as a reference.
2. Connect the diode in series with either supply output to prevent the battery from
discharging through the internal OVP crowbar transistor. The diode must be
mounted on a suitably-rated heatsink to prevent its case temperature from
exceeding the manufacturer's maximum limits.
Peak Charging Current
Maximum Voltage
Diode Type
250-350A
40V
Two (2) parallel MBR30045CT
60-249A
40V
One (1) MBR30045CT
25-59A
100V
One (1) MUR7015
10-24A
300V
One (1) MUR3040PT
5-9A
500V
One (1) MUR1560
<5A
600V
One (1) MUR758
TM-25OP-01XN.book Page 86 Monday, April 5, 2004 8:58 AM
Содержание XKW 12-150
Страница 2: ......
Страница 3: ...Operating Manual for XKW 3000 Watt Series Programmable DC Power Supply...
Страница 14: ...xii Operating Manual for XKW 3kW Series Power Supply...
Страница 18: ...List of Tables xvi Operating Manual for XKW 3kW Series Power Supply...
Страница 28: ...Features and Specifications Specifications 26 Operating Manual for XKW 3kW Series Power Supply...
Страница 48: ...Installation Using Remote Sensing 46 Operating Manual for XKW 3kW Series Power Supply...
Страница 80: ...Operation Using Multiple Supplies 78 Operating Manual for XKW 3kW Series Power Supply...
Страница 89: ......