A
C
Wi
r
i
ng
975
-
0367
-
01
-
01
2
–
17
This manual for use by qualified installers only
T
a
b
l
e
2-7
Mi
n
.
R
e
c
o
mme
nd
e
d
Wi
r
e
S
ize
,
T
o
r
qu
e
V
a
l
u
e
s
,
a
nd
M
a
x
.
O
u
t
pu
t
B
r
e
a
ke
r
S
ize
a
a.Table 2-7 is based on installation with conduit using no more than three 75°C copper conductors in a
maximum 30°C ambient, and then applying the worst case conditions between the CEC Part I 2006
Edition, Table 2 and the NEC ANSI/NFPA 2005 Edition, Table 310.16.
I
n
v
e
r
t
e
r
M
od
e
l
A
C
I
n
p
u
t
A
C
O
u
tp
u
t
T
o
r
q
u
e
V
a
l
u
e
fo
r
T
e
r
m
i
n
a
l
C
o
nn
e
c
t
i
o
n
s
Ma
x
i
m
u
m
O
u
tp
u
t
B
r
eake
r
S
i
z
e
TR1512-120-60
#6 AWG (13.6 mm
2
) #10 AWG (3.3 mm
2
) 16 in-lbs (1.8 Nm) max. 30 amps AC
TR2412-120-60
#6 AWG (13.6 mm
2
) #10 AWG (5.2 mm
2
) 16 in-lbs (1.8 Nm) max. 30 amps AC
TR1524-120-60
#6 AWG (13.6 mm
2
) #10 AWG (3.3 mm
2
) 16 in-lbs (1.8 Nm) max. 30 amps AC
TR2424-120-60
#6 AWG (13.6 mm
2
) #10 AWG (5.2 mm
2
) 16 in-lbs (1.8 Nm) max. 30 amps AC
TR3624-120-60
#6 AWG (13.6 mm
2
) #8 AWG (8 mm
2
)
16 in-lbs (1.8 Nm) max. 45 amps AC
TR1512-230-50
#10 AWG (5.2 mm
2
) #14 AWG (2.0 mm
2
) 16 in-lbs (1.8 Nm) max. 15 amps AC
TR1524-230-50
#10 AWG (5.2 mm
2
) #14 AWG (2.0 mm
2
) 16 in-lbs (1.8 Nm) max. 15 amps AC
TR2424-230-50
#10 AWG (5.2 mm
2
) #14 AWG (2.0 mm
2
) 16 in-lbs (1.8 Nm) max. 15 amps AC
W
A
R
N
I
NG
:
Fi
r
e
H
a
z
a
r
d
To reduce the risk of fire, connect only to a circuit provided with the maximum
branch-circuit overcurrent protection noted above in accordance with your local electrical
codes.
I
m
po
r
t
a
n
t
:
Various local electrical codes require conduit be used in this type of
installation. Refer to the local electrical codes (for example, the NEC in the U.S.) to verify
if it is needed in your installation. Conduit fittings can be replaced with strain reliefs
where code permits.
W
A
R
N
I
NG
:
S
h
o
c
k
H
a
z
a
r
d
Disconnect the battery cables from the inverter if they are already connected.
http://www.wholesalesolar.com/inverters.html
http://www.wholesalesolar.com/inverters.html
Содержание TR1512-120-60
Страница 2: ...http www wholesalesolar com inverters html http www wholesalesolar com inverters html ...
Страница 8: ...vi http www wholesalesolar com inverters html http www wholesalesolar com inverters html ...
Страница 16: ...xiv http www wholesalesolar com inverters html http www wholesalesolar com inverters html ...
Страница 18: ...xvi http www wholesalesolar com inverters html http www wholesalesolar com inverters html ...
Страница 64: ...2 34 http www wholesalesolar com inverters html http www wholesalesolar com inverters html ...
Страница 69: ...http www wholesalesolar com inverters html http www wholesalesolar com inverters html ...