Battery cables
a.
Remove the DC fuse from the fuse holder on the red pos(+)
battery cable.
b.
Connect the battery's red pos(+) cable to the charge
controller's pos(+) terminal.
c.
Connect the battery's black neg(–) cable to the charge
controller's neg(–) terminal.
d.
Connect the battery's red pos(+) cable to the battery's pos
(+) terminal.
e.
Connect the battery's black neg(–) cable to the battery's neg
(–) terminal.
IMPORTANT
: Always follow the battery manufacturer's
recommendations. See for possible lead-acid battery
configurations. Do not configure 12-volt 4-cell LiFePO
4
batteries.
PV cables
a.
Cover the solar panel with a blanket to avoid energizing the
cables.
b.
Install a PV Disconnect device on the red pos(+) PV cable.
Install it closer to the solar panel's pos(+) terminal. Keep it
open.
c.
Connect the red pos(+) PV cable with an open PV disconnect
device to solar panel's pos(+) terminal and the charge
controller's PV pos(+) terminal.
d.
Connect the black neg(–) PV cable to the solar panel's neg
(–) terminal and the charge controller's PV neg(–) terminal.