SETUP & HISTORICAL DATA
The following table is a summary of the major values that may be changed through
Setup or by accumulating historical data. The column on the right is provided to write down
your setup values or historical data. Be sure and know these values before calling for
customer service. Multiply values by two for 24-volt systems.
PARAMETER
DEFAULT Bat. 1 Bat.2
BATTERY VOLTS
CHARGED
13.2 V
_________ ________
BATTERY AMPS
CHARGED
2%
_________ ________
BATTERY CAPACITY
200 Ah
_________ ________
DATA
Bat. 1 Bat.2
CEF
_________ ________
# OF CEF RECALC'S
_________ ________
AVG DEPTH OF DISCHARGE
_________ ________
DEEPEST DEPTH OF DISCHARGE
_________ ________
FUNCTIONS
DEFAULT
Bat. 1 Bat.2
DISPLAY SCAN (F01)
Off
_________ ________
DISPLAY SLEEP (F02)
ON
_________ ________
AMBIENT TEMP. (F03)
70 °F
_________ ________
Ah/kWh
(F04)
Ah displayed
_________ ________
ALT. ENERGY
(F05)
Off
_________ ________
Manual
CEF
(F06)
95% This value should
only be set if you do NOT
want your
Link 20
to
automatically calculate
CEF
_________ ________
TEMP. COEF.
(F07)
0.5
_________ ________
PEUKERT EXP. (F08)
1.25
_________ ________
DISCH. FLOOR (F09)
100%
_________ ________
BATTERY TYPE (F10)
#1 LIQUID LEAD ACID _________ ________
SOFTWARE REV. (F15)
(Same for either battery) _________ ________