![Xantrex Smart mini Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/xantrex/smart-mini/smart-mini_owners-manual_3176249010.webp)
10
Your
Link 20
comes with default
values chosen to work with most systems.
Normally the only values that need to be
changed are the battery capacity, battery
type (liquid or gelled), and high discharge
rate compensation (Peukert) exponent.
Please be sure you understand each
function before changing the factory
default values outlined below.
Holding the
SET
button for five seconds accesses the
Set Up
and
Advanced
Functions
. The display will read
SEL
. If you press
SEL
once, you will display the first
Setup variable: Charged Voltage. Pressing
SEL
repeatedly will step through more variables:
Charged Current, battery amp hour capacity, and averaging period for Time Remaining.
Corresponding status lights come on for each.
If you continue pressing
SEL
, you will step through
functions
named in small text
below each of the lights on the Battery 1 Light Bar. Some
functions
have multiple displays.
These are described in later pages devoted to
RESET
,
DATA
, and
LOCK
ing
of your
meter. The next (right) battery status light indicates you've entered the
Advanced
FUNC
tions
area (see page 17).
When a desired
variable
or
function
is displayed, pressing the
SET
button will
display the present value of the function. Pressing
SET
again will display the next choice.
If you
hold
the
SET
button, the display begins scrolling. When the desired value appears,
release the button. If the button is held down longer, the display will increment to the end
of its range, then roll over to its minimum value and continue to scroll.
If this sounds complicated, relax! It's not. Once you go through it a few times, it will
become second nature. On the next page, we'll go through this again step-by-step.
FACTORY DEFAULT VALUES
Monitoring Functions:
Charged Voltage
= 13.2 volts for 12-volt systems
= 26.4 volts for 24-volt systems
Charged Current
= 2% (of battery capacity, 4 amps @ 200 Ah)
Battery Capacity
= 200 Ah
CEF
= 95% (
C
harge
E
fficiency
F
actor)
Ambient Temp.
= 70
o
F
Battery Type
= #1 (Liquid cells)
Peukert Exponent
= 1.25
SETUP PROCEDURES
i4.25