13
HOW TO SET
Your
Link 20
automatically selects an appropriate charged voltage for 12-volt
liquid and gel cells when you set battery type. (We'll cover setting battery type on page
19). If you operate a 24-volt system, or if extremes of temperature are involved, here's
how to change charged voltage:
1.
Press
SET
for five seconds.
SEL
will appear in the numeric display.
2.
Press
SEL
once.
The light will come on and
13.2
will
appear in the numeric display.
3.
Press and hold
SET
.
The numeric display will move up in
0.1
volt
steps until
50.0
volts is displayed. The
display will then "wrap around" and
start counting up from
8.5
volts. Stop at the
desired voltage.
4.
After 10 seconds, the displayed
setting is stored in memory and
normal operation resumes.
HOW TO SET
The
Link 20
is factory set to use 2% of battery capacity as Charging Current
Percentage. If you normally end charging before 2% is reached, or use a very large
battery bank, such as might be encountered in an alternative energy installation, a different
value may be appropriate. Here's how to change it:
1.
Press
SET
for five seconds.
SEL
will appear in the numeric display.
2.
Press
SEL
twice.
The light will come on and
2
will
appear in the numeric display.
3.
Press and hold
SET
.
The numeric display will move up in
1
percent
steps until
7
percent is displayed. The
display will then "wrap around" and
start counting up from
1
percent.
4.
After 10 seconds, the displayed
setting is stored in memory and
normal operation resumes.