20
F11 - Not Used
F12 - Not Used
F13 - Not Used
F14 - DISPLAY TEST
DEFAULT: OFF
RANGE: ON when SET button is depressed when
this function is active.
OFF when SET is released.
This function confirms proper operation of the
Link 20
front panel display. When
the SET button is pressed in the F14 mode, the two top left lights on the battery light bar
will be an orange/yellow color. All other lights will display their normal color and the numeric
display will read -188.8. The display will return to normal when the SET button is released.
Operation of the two right (green) lights on the battery light bar is confirmed when power
is initially applied to your
Link 20
.
F15 - DISPLAY SOFTWARE REVISION NUMBER
Function F15 selects display of the software revision number. This number is used
internally with Xantrex Technology to keep track of which version of software is installed
in your
Link 20
. This number should be written down in the Setup table contained in this
manual for your future reference.