Troubleshooting
5–4
No output voltage;
OVER
TEMP
indicator on; load is
more than 1750 W / 15 A
output current. The
AMPS
indicator is showing high
battery current.
Thermal shutdown.
Allow the unit to cool off.
Reduce the load if continuous
operation is required.
No output voltage; the
OVER
TEMP
indicator is on; the
load is less than 1750 W /
15 A output current.
Thermal shutdown.
Improve ventilation; make sure the
PROwatt 1750’s ventilation openings
are not obstructed; reduce the ambient
temperature.
No output voltage; the
OVER
LOAD
indicator is on.
Short circuit or wiring error.
Very high power load.
Check the AC wiring for a short circuit
or improper polarity (hot and neutral
reversed).
Remove the load.
Table 5-1 Troubleshooting Reference
Problem
Possible Cause
Solution