Connecting DC Cables
3–15
To connect the DC cables:
1. Cut the cables to the correct length.
2. Strip the appropriate amount of insulation from one end of each cable
and attach the connectors that will join the cables to the battery,
battery isolator switch, or fuse block. The connectors you use must
create a permanent, low-resistance connection.
If you are using crimp connectors, use the tool recommended by the
terminal manufacturer. Make sure no stray wires protrude from the
terminal. (You may find it more convenient to have the crimp
connectors attached by the company that sells you the cable.)
3. For each cable end that will be connected to the inverter, strip the
appropriate amount of insulation from the cable and attach the
connector that will join the cable to the cabling terminal.
Figure 3-6 Configuration for Heavy Loads
FROM ALTERNATOR
OR CHARGER
TO VEHICLE
VEHICLE
STARTING
BATTERY
DEEP-CYCLE
BATTERY
DEEP-CYCLE
BATTERY
DEEP-CYCLE
BATTERY
DEEP-CYCLE
BATTERY
FUSE OR
CIRCUIT
BREAKER
FUSE OR
CIRCUIT
BREAKER
BATTERY
SELECTOR
SWITCH
BATTERY ISOLATOR
BATTERY
SELECTOR
SWITCH
TO DC
LOADS
PROwatt
1750
GROUND TO
VEHICLE
CHASSIS
GROUND TO
VEHICLE
CHASSIS
GROUND TO
VEHICLE
CHASSIS
ALL
OFF
2
1
ALL
OFF
2
1
FUSE OR
CIRCUIT
BREAKER
FUSE OR
CIRCUIT
BREAKER
Содержание PROwatt 1750
Страница 1: ...Owner s Guide PROwatt 1750 Inverter...
Страница 6: ...vi...
Страница 12: ...xii...
Страница 16: ...1 4...
Страница 22: ...2 6...
Страница 40: ...3 18...
Страница 48: ...4 8...
Страница 64: ...B 10...
Страница 68: ...C 4...
Страница 74: ...D 6...