Configuration
4–12
445-0089-01-01
Configure Battery Menu
Menu Display
(if different from Menu Item)
Menu Items
Access
Battery Size
Installer
Dflt Batt Temp
Default Batt Temp
User
Battery Type
Installer
View / Change Battery Details:
Batt Temp Coeff
Mode Settings: Bulk Charge
• Bulk - Maximum Voltage
• Bulk - Maximum Current (%C)
a
• Bulk - Threshold Voltage
• Bulk - Threshold Timeout
a.%C is used as the unit of measure for the current setpoints in the Configure Battery menu. The meaning of %C is as follows: Charg-
ing current generally varies with battery bank size. Therefore, current setpoints are generally expressed as %C where C is the ca-
pacity (Ah) of the battery bank. For example, to charge a 200Ah battery bank at 40A, a setting of 20% should be used.
View / Change Battery Details:
Battery Temp. Coefficient
Mode Settings: Bulk Charge
• Max Voltage
• Max Current (%C)
a
• Threshold Voltage
• Threshold Timeout
Installer
Installer
Installer
Installer
Installer
Mode Settings: Absorption Chrge
• Absorption - Max Voltage
• Absorption - Max Current (%C)
a
• Absorption - Max Timeout
• Absrptn - Threshld Current (%C)
a
• Absrptn - Threshld Timeout
Mode Settings: Absorption
• Max Voltage
• Max Current (%C)
a
• Max Timeout
• Threshold Current (%C)
a
• Threshold Timeout
Installer
Installer
Installer
Installer
Installer
Mode Settings: Overcharge
• OverChg - Maximum Voltage
• OverChg - Maximum Current (%C)
a
• OverChg - Maximum Timeout
Mode Settings: Overcharge
• Max Voltage
• Max Current (%C)
a
• Max Timeout
Installer
Installer
Installer
Mode Settings: Float
• Float - Maximum Voltage
• Float - Maximum Current (%C
a
)
• Float - Maximum Timeout
• Float - Threshold Voltage
• Float - Threshold Timeout
Mode Settings: Float
• Max Voltage
• Max Current (%C
a
)
• Max Timeout
• Threshold Voltage
• Threshold Timeout
Installer
Installer
Installer
Installer
Installer
Mode Settings: Equalize Charge
• Equalize - Maximum Voltage
• Equalize - Maximum Current (%C)
a
• Equalize - Maximum Timeout
• Equalize - Threshld Change
• Equalize - Threshld Timeout
Mode Settings: Equalize
• Max Voltage
• Max Current (%C)
a
• Max Timeout
• Threshold Change
• Threshold Timeout
Installer
Installer
Installer
Installer
Installer
Mode Settings: Constant Charge
• Constant Voltage Setpoint
• Constant Current Setpoint
Mode Settings: Constant
• Voltage Setpoint
• Current Setpoint
Installer
Installer
Charger Mode
Charger Mode
Installer
Charger Type
Charger Type
Installer
CHG Hi V Warning Offset
Charger Hi V Warning Offset
Installer
Содержание PROsine 2.0
Страница 1: ...PROsine 2 0 Inverter Charger User s Manual...
Страница 2: ......
Страница 3: ...PROsine 2 0 Inverter Charger User s Manual...
Страница 8: ...vi...
Страница 12: ...x...
Страница 18: ...xvi...
Страница 20: ...xviii...
Страница 68: ...Installation 3 26 445 0089 01 01...
Страница 120: ...Series Operation 7 12 445 0089 01 01...
Страница 128: ...A 8...
Страница 132: ...B 4...
Страница 147: ......