Electrical Specifications: Charge Mode
445-0089-01-01
A–3
Electrical Specifications: Charge Mode
AC Input
Operating voltage range
90–135Vac
Nominal current
15Aac at 100A charge, 120Vac in
Power factor (100A charge, 120Vac in)
≥
0.98 on sine input
Nominal frequency
60Hz
DC Output
Nominal voltage
12.0Vdc
Min battery voltage for charging
0.0Vdc
Max output voltage
17.5Vdc
Nominal output current
100A @
≤
15.0Vdc
Equalize mode max current
≥
10A @
≤
17.5Vdc
Charger current derating
Automatically reduce charger current as internal
temperature exceeds 80
°
C, input Vac
approaches low transfer, and ac input current
approaches 80% of breaker setting.
Efficiency at nominal output
≥
84%
Other
Battery type settings
Gel, Flooded, AGM, Pb-Ca
Battery size settings
50–2000 Ahr
Charge algorithms
Custom 3-stage with factory default set points.
Custom 2-stage as above.
Manually engaged, equalize, with factory
defaults.
CV/CC. User programmable setpoints.
Independent battery banks
1