Operation
Command Syntax
Release 1.2
35
Command
Strings
If you send more than one command line, separate the commands with a semicolon.
The semicolon may be preceded or followed by spaces.
Example:
Command
Terminators
Terminators indicate the end of a command string and tell the power supply to
execute the command. The termination character is LF (Line Feed).
Format:
COMMAND <parameter>; COMMAND <parameter>, <parameter><LF>
Most computer controllers automatically send LF with output statements.
Order
You may send commands in any order, keeping in mind that only those commands
received after a HOLD and before a TRG (trigger) will be released by the TRG
command. In addition, only these commands received after a supply disable and
before a RST (reset) or OUT ON command will be released by the RST command
or the OUT command. Commands are executed in the order they are received.
ISET 2.0A; VSET 5V
ISET 2.0A; VSET 5V