AC/DC and GFCI Panel
8
Freedom XC Owner's Guide
AC/DC and GFCI Panel
6
3
2
1
7
14
13
12
13
8
11
9
10
4
5
5
12
Figure 2 AC/DC and GFCI Panel
WARNING
ELECTRICAL SHOCK HAZARD
Use a torque screwdriver to tighten the captive nut panel screw to
5 in-lb (0.56 N-m) torque of force to ensure a proper ground
connection and a required tool access to the wiring compartment.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Item
Description
1
ACC input terminal
for connecting ignition control wiring.
Ignition Control Switch (ACC) for connecting [ON (|)] and
disconnecting [OFF (O)] the ignition signal.
2
Remote port
allows you to connect an accessory remote
control / display device.
3
Captive nut panel screw
holds the wiring compartment
cover in place. See WARNING above.
4
Ventilation grille
(openings) must not be obstructed.
5
Grounding lug
provides a ground path for the Freedom
XC chassis to the DC system ground. See WARNING.
6
DC terminal
opening for routing (–) negative DC cable.
Table 1 AC/DC and GFCI Panel Features
Содержание Freedom XC 1000
Страница 1: ...Freedom XC Inverter Charger Owner s Guide Freedom XC 1000 817 1050 Freedom XC 2000 817 2080 ...
Страница 6: ...This page is intentionally left blank 2 ...
Страница 22: ...This page is intentionally left blank 2 ...
Страница 28: ...This page is intentionally left blank 2 ...
Страница 56: ...This page is intentionally left blank 2 ...
Страница 98: ...This page is intentionally left blank 2 ...
Страница 107: ...This page is intentionally left blank 1 ...