Side Panel
975-0784-01-01
11
Side Panel
1
2
4
3
Figure 4 Side Panel
WARNING
ELECTRICAL SHOCK HAZARD
n
Use a torque screwdriver to tighten the captive nut panel
screw to 5 in-lb (0.56 N-m) torque to ensure a proper
ground connection and a required tool access to the wiring
compartment.
n
Use a torque screwdriver to tighten the bolt on the DC
ground lug to a torque of 23 in-lb (2.6 N-m) of force.
n
Apply an anti-corrosion compound to the copper wire prior
to connecting to the DC ground lug.
Failure to follow these instructions can result in death, serious
injury, or equipment damage
.
Item
Description
1
Captive nut panel screw
holds the wiring compartment
cover in place. See WARNING above.
2
Wiring compartment cover
protects the wiring
compartment from debris and keeps the cables secure.
Using the captive nut panel screw, the cover can be
opened and lifted out during wiring. See WARNING on the
left.
3
20 A supplementary protector with reset button
provides overload protection for the optional GFCI kit (sold
separately; order PN: 808-9817). Press to recover from an
overload condition. In a hard wired installation, the
supplementary protector does not protect output wiring.
4
Grounding lug
provides a ground path for the Freedom
XC chassis to the DC system ground. See WARNING.
Table 3 Side Panel Features
Содержание Freedom XC 1000
Страница 1: ...Freedom XC Inverter Charger Owner s Guide Freedom XC 1000 817 1050 Freedom XC 2000 817 2080 ...
Страница 6: ...This page is intentionally left blank 2 ...
Страница 22: ...This page is intentionally left blank 2 ...
Страница 28: ...This page is intentionally left blank 2 ...
Страница 56: ...This page is intentionally left blank 2 ...
Страница 98: ...This page is intentionally left blank 2 ...
Страница 107: ...This page is intentionally left blank 1 ...